Moxa Technologies NE-4100 user manual Change Password, Load Factory Defaults, Save/Restart

Page 56

NE-4100 Series User’s Manual

Web Console Configuration

Change Password

Click on the Change Password link on the left side of the screen to display the Change Password window. Make necessary changes to the settings and click on Submit to validate the modifications.

Input the “Old password” and “New password” to change the password. Leave the password boxes blank to erase the password. In this case, the NE-4100 will not have password protection.

If you forget the password, the ONLY way to configure NE-4100 is by using the Reset button on the NE-4100 Series’ evaluation boards to “Load Factory Defaults.”

Remember to export the configuration file using Windows Administrator when you finish the configuration. By using the Import function of Windows Administrator, your configuration can be re-loaded into NE-4100 after using “Load Factory Default.” Refer to Chapter 7 for more details about the Export and Import function.

Load Factory Defaults

To load the factory default settings, click on the Load Factory Default link on the left side of the screen and then click on Submit to restore the factory default settings. Note that by doing so the modifications you made before will be lost.

Save/Restart

Click on the Save/Restart link on the left side of the screen if you would like to restart the configuration. After all changes have been made and applied, click on Submit to exit the system.

6-21

Image 56
Contents NE-4100 Series User’s Manual Sixth Edition, AprilCopyright Notice Table of Contents Chapter Configuring Windows Administrator Introduction Overview Package ChecklistProduct Features Product Specifications Panel Layout and Pin Assignments NE-4120 Series/NE-4120-STNE-4100T/NE-4100-ST Panel LayoutsNE-4100T NE-4100-STPin Assignments RXD1LED Name LED Color LED Function Block DiagramNE-4100-ST LED Indicators NE-4110 Series/NE-4110-ST NE-4110SNE-4110A NE-4110-ST evaluation board for NE-4110 SeriesSerial Header Pinouts J1 for NE-4110S Serial Header Pinouts J1 for NE-4110AEthernet Port Pinouts for NE-4110S/A DIO and LED Header Pinouts J2 for NE-4110S/ANE-4110A Block Diagram Block DiagramsNE-4110S Block Diagram NE-4110-ST LED Indicators NE-4120 Series/NE-4120-ST Top Panel of NE-4120STop Panel of NE-4120A NE-4120-ST evaluation board for NE-4120 SeriesSerial Header Pinouts J1 for NE-4120S Serial Header Pinouts J1 for NE-4120ANE-4120S Block Diagram NE-4120A Block DiagramNE-4120-ST LED Indicators Getting Started Wiring Requirements Attaching NE-4100T to the Evaluation BoardAttaching NE-4110 Series to the Evaluation Board Attaching NE-4120 Series to the Evaluation BoardCircuit Pad for External Connection Connecting the Power Connecting to the NetworkConnecting to a Serial Device DI/O SettingsDigital Output LED Circuit Design Selecting the Interface JP2Choosing the Proper Operation Mode TCP Server Mode TCP Client Mode UDP ModeReal COM Mode Initial IP Address Configuration ARPFactory Default IP Address NE-4100 Series Administration SuiteDefault IP address Initializing NE-4100 Series Module’s IP AddressTelnet Console Page Serial Console 19200, n, 8 Web Console Configuration Opening Your Browser Time zone Basic SettingsServer name Setting Factory Default Necessity Time serverIP Address Network SettingsMethod Function Definition Setting Factory Default Necessity 255.255.255.0 Required Setting Factory Default Necessity None OptionalIP configuration GatewayCommunity name ContactLocation Auto report to IPSerial Settings Operating Settings TCP Server ModeMax connection Max. connectionMax connection 2 to DelimiterReal COM Mode Setting Factory Default Necessity 4001 RequiredCommand port Setting Factory Default Necessity 966 OptionalNE-4100 Series User’s Manual Web Console Configuration TCP Client Mode Destination IP address 1/2/3/4 UDP Mode TCP connection onLocal Listen port Accessible IP Settings # Hosts on a given subnet can access the NE-4100# Any host can access the NE-4100 Allowable Hosts Input formatAuto Warning Settings Mail and Snmp TrapEvent Type Digital IO DIO MonitorSave/Restart Change PasswordLoad Factory Defaults Configuring Windows Administrator Monitor Port Monitor COM MappingInstalling Network Enabler Administrator NE-4100 Series User’s Manual Web Console Configuration Starting the Configuration Broadcast SearchNE-4100 Series User’s Manual Web Console Configuration Unlock Password Protection Lock UnlockBlank FixedConfiguring NE-4100 Upgrading the Firmware Export/Import Monitor Select Add Target NE-4100 Series User’s Manual Web Console Configuration NE-4100 Series User’s Manual Web Console Configuration Port Monitor COM Mapping On-line COM MappingSelect COM Setting to modify COM No., default setting, etc NE-4100 Series User’s Manual Web Console Configuration Off-line COM Mapping SW Reset Function NE-4100 Series User’s Manual SW Reset Function TCP Socket Application Service Well Known Port NumbersUDP Socket Application Service NE-4100 Series User’s Manual Well Known Port NumbersNeci Library DIO Commands Command Packet Format Length Bytes Header DataACK Packet Format Length Bytes Header Data Data Structure DefinitionCommand Code Usage Reading Single DIO Parameters Writing a Single DIO ParametersNE-4100 Series User’s ManualDIO Commands Reading Multiple DIOsWriting Multiple DIOs Snmp Agent with MIB II & RS-232 Like Group System MIB Interfaces MIB Address Translation MIBService Information Moxa Internet Services Following services are providedSerial Number Problem Report FormMoxa Product & NE-4100T Product Return Procedure