Moxa Technologies user manual Smartio CP-168U User’s Manual

Page 54

13.Click OK in the Port X dialog box to confirm the port settings, and then click OK in the Property dialog box to complete the port settings and return to the MOXA Smartio/Industio Configuration Panel dialog box. The configured CP-168U board will now appear in the MOXA Smartio/Industio Configuration Panel dialog box, as shown below.

14.Click OK in the MOXA Smartio/Industio Configuration Panel to return to the Network dialog box, and then click OK to exit the Network dialog box.

15.Restart the PC.

NOTE The driver configuration will NOT take effect until you restart the PC.

NOTE

Double check that all Smartio CP-168U board components—the control board—are connected and

fastened tightly to make sure that the system and the driver can start up successfully.

 

Once the system restarts, you may check the event log issued by the MOXA driver to see if the board’s ports have been initialized successfully.

Enter the [Administrative] group, click the [Event Viewer] icon, and then select [Log] and [System] to check a message similar to “MOXA CP-168U board, with first serial port COM3, has been enabled” for each newly configured board.

NOTE

If an error message similar to “Cannot find any configured MOXA Smartio/Industio series board!”

pops up, refer to the Troubleshooting chapter for possible solutions.

 

3-38 Smartio CP-168U User’s Manual

Image 54
Contents Smartio CP-168U User’s Manual Page Copyright Notice TrademarksDisclaimer Page Moxa Internet Services Page Table of Contents Introduction OverviewPCI Solution Surge ProtectionOperating System Support Moxa Serial Comm Tool Features Package Checklist 136.9 × 100 mm 5.39 × 3.94 in CP-168U Installation Guide InstallationPage Hardware Installation Installing the Smartio CP-168U boardSmartio CP-168U User’s Manual Software Installation WindowsInstalling the Driver Software Installation Smartio CP-168U User’s Manual Software Installation How to Check the Installation Using Device ManagerPort Configuration Smartio CP-168U User’s Manual Using PComm Using Event Log Windows 2000/XPPlay devices Click on Next to continue Smartio CP-168U User’s Manual Software Installation Smartio CP-168U User’s Manual Software Installation Smartio CP-168U User’s Manual Device Manager Port Configuration Software Installation Moxa PComm Utility Event LogRemoving the Driver Click on OK to proceed with the un-installation of the board Windows 95/98 Installing the Driver First Time Driver Installation Windows Software Installation Board and Port Ready Configuring the Board and Ports Smartio CP-168U User’s Manual Updating the Driver Removing the Driver Windows NT Installing the Driver Software Installation Smartio CP-168U User’s Manual Smartio CP-168U User’s Manual Software Installation Smartio CP-168U User’s Manual Configuring the Board and Ports Re-Configuring Port SettingsConfiguring Another CP-168U Board Removing an Existing CP-168U Board Configuration Removing the Driver DOS Setting up the Driver Software Installation Port number TxD buffer sizeRxD buffer size F5 Group EditLinux SCO Smartio CP-168U User’s Manual Bus/Dev No Smartio CP-168U User’s Manual Software Installation Page PComm Installation Serial Programming ToolsPComm Programming Library Diagnostic for Moxa boards only UtilitiesMonitor for Moxa boards under Windows NT/2000/XP/2003 Terminal Emulator Connection Cables and Cable Wiring RS-232 Cable WiringDB62 Female Connector Pinouts DB-9/M Pin Assignment Opt8-M9, Opt8D DB-25/M Pin Assignment Opt8B/CDB-25/F Pin Assignment Opt8A/S RJ45 Pin Assignment Opt8-RJ45DB-25/F Pin Assignment Opt8F/Z DB-25/F Pin Assignment Opt8KTroubleshooting General TroubleshootingWindows NT system panics blue screen Troubleshooting Page Specifications Technical ReferenceMoxa Uart Return Procedure Revision History
Related manuals
Manual 63 pages 28.34 Kb