Table C. Troubleshooting with
Indicator Color | Meaning | Possible Cause |
| Corrective Action | ||
|
|
|
|
|
|
|
| Fiber Failover Mode LED ( |
|
| ) |
| |
|
|
| ||||
|
|
| ||||
|
|
|
|
|
| |
Not lit | The module is not in | The FX Mode switch is set | If fiber redundancy is not | |||
| fiber redundancy | to position 0. |
| required, no action is | ||
| mode. |
|
|
|
| required. If fiber redundancy |
|
|
|
|
|
| is required, power off the |
|
|
|
|
|
| module, set the FX Mode |
|
|
|
|
|
| switch to position 1 or 2 as |
|
|
|
|
|
| appropriate, and then power |
|
|
|
|
|
| on the module. For detailed |
|
|
|
|
|
| information, refer to the |
|
|
|
|
|
| Setting Fiber Failover Mode |
|
|
|
|
|
| section. |
|
|
|
|
|
| |
Green | The module is in | The FX Mode switch is set | If fiber redundancy is | |||
| fiber redundancy | to position 1 (port A |
| required, no action is | ||
| mode. The primary | connects to the primary | required. If fiber redundancy | |||
| fiber link is | fiber link) or to position 2 | is not required, power off the | |||
| operational. The | (port B connects to the |
| module, set the FX Mode | ||
| secondary fiber link | primary fiber link). |
| switch to position 0, and | ||
| is idle. |
|
|
|
| then power on the module. |
|
|
|
|
|
| |
Amber | The module is in | A problem exists with the | Refer to the Optic Fault LED | |||
| fiber redundancy | secondary fiber link. The | section or to the | |||
| mode. The primary | Optic Fault LED or the |
| Status LED section in this | ||
| fiber link is | table as appropriate. | ||||
| operational. The | port A or port B is red. |
|
| ||
| secondary fiber link |
|
|
|
|
|
| is down. |
|
|
|
|
|
|
|
|
|
|
| |
Flashing amber | The module is in | A problem exists with the | Refer to the Optic Fault LED | |||
| fiber redundancy | primary fiber link. The Optic | section or to the | |||
| mode. The primary | Fault LED or the |
| Status LED section in this | ||
| fiber link is down. | table as appropriate. | ||||
| The secondary fiber | port A or port B is red. |
|
| ||
| link is operational. |
|
|
|
|
|
|
|
|
|
|
| |
Red | The module is in | A problem exists with the | Refer to the Optic Fault LED | |||
| fiber redundancy | primary and backup fiber | section or to the | |||
| mode; however, both | links. The Optic Fault LEDs | Status LED section in this | |||
| primary and | or the | table as appropriate. | |||
| secondary fiber links | LEDs for ports A and B are |
| |||
| are down. | red. |
|
| ||
|
|
|
|
|
|
|
(Continued on next page)
C2624M (6/07) | 23 |