Pelco FX82012 manual Specifications

Page 31

Specifications

PERFORMANCE

 

Switch Type

Unmanaged Layer 2

Switch Method

Store and forward

Switch Fabric

Non-head-of-line blocking

Data Rate

10/100 Mbps

Compliance

IEEE 802.3, 802.3u, 802.3x

Interface

Auto MDI/MDI-X

Operating Mode

Half-duplex or full-duplex

Address Table Size

1,024 MAC address entries with automatic learning and aging

Quality of Service

IEEE 802.1p priority, tag-based, four queues per port,

 

weighted fair queuing scheduling

Maximum Frame Size

Untagged Ethernet frames up to 1,518 bytes

 

Tagged Ethernet frames up to 1,522 bytes

GENERAL

 

Operating Temperature

-40° to 167°F (-40° to 75°C)

Input Power Requirements

12 VDC or 24 VAC, 0.50 A

LED Indicators

Power

 

Fiber Redundancy Mode Status

 

100BASE-FX Port Status (link/activity, FEFI per fiber port)

 

Optic Fault (optic signal/laser status per fiber port)

 

10BASE-T/100BASE-TX Port Status (two LEDs:

 

link/activity and speed, duplex/collision and speed)

Dimensions

8.75" D x 1.08" W x 4.81" H

 

(22.23 x 2.74 x 12.22 cm)

Unit Weight

1.6 lb (0.73 kg)

MECHANICAL

 

Connectors

 

Rack Power/Alarm

One 4-pin connector

Stand-Alone Power

One 2-pin connector, screw terminal

Electrical

One RJ-45, 10BASE-T/100BASE-TX

Fiber Optic

Two single-fiber ST or SC

C2624M (6/07)

31

Image 31
Contents Ethernet Switch List of Illustrations ContentsRJ-45MDI/MDI-X Connector Pinouts FX Mode Switch SettingsList of Tables Important Safety Instructions Risk of Electric Shock Do not Open Radio and Television Interference Regulatory NoticesDescription Product OverviewC2624M 6/07 Single-Mode Models*† ModelsFX82012 module consists of the following series of models Multimode ModelsIllustrates the front panel of the FX82012 module Front PanelIllustrates the rear panel of the FX82012 module Rear PanelPackage Contents Installation10BASE-T/100BASE-TX Modes of Operation Autonegotiation is enabled by defaultFlow control is disabled by default Flow control default settingFX Mode Switch Setting Fiber Failover ModeMounting Mode of OperationMounting the FX82012 Module to a Wall PAN Head with Wall Clip Lock Washer Connections Fiber connections Primary Fiber Port Connections in Sample Drop-and-Repeat Application Module Reseat module or power Supply as necessary TroubleshootingReplace power supply Meaning By the remote link Indication Fefi On local module Optical signalOptic Fault LED on local Section in this table Replace local moduleMeaning Possible Cause Corrective Action Optic Fault LED Established Table D. Troubleshooting with Rear-Panel IndicatorsAmber If 10BASE-T operation isMeaning Possible Cause Corrective Action Amber Port is set to Duplex mode LinkRefer to the Setting If half-duplex mode isTion or by manually Green Port is set to If 100BASE-TX full-duplexFull-duplex operation is not Flashing green Port is set toTable D. Troubleshooting with Rear-Panel Indicators Specifications Multimode 62.5/125 μm PowerWavelength Optical Maximum BudgetIllustrates RJ-45 MDI/MDI-X connector pinouts Appendix. RJ-45 Connector PinoutsC2624M 6/07 Product Warranty and Return Information ISO9001