Sun Microsystems SG-XPCIE20FC-NEM-Z manual Tables

Page 9

Tables

TABLE 1-1

NEM Features and Specifications 2

 

TABLE 1-2

Supported Operating System Versions

4

TABLE 1-3

Platform and Operating System Support

5

TABLE 2-1

Optical Cable Specifications 11

 

TABLE 2-2

Port LED Indicator Status Definitions 13

TABLE 2-3

NEM LED Status 18

 

ix

Image 9
Contents For HBA Model SG-XPCIE20FC-NEM-Z Please Recycle Contents HBA Software Installation Contents Page Figures Page Tables Page How This Document Is Organized PrefaceShell Prompts Using Unix CommandsRelated Documentation Typographic ConventionsDocumentation, Support, and Training Third-Party Web SitesSun Welcomes Your Comments Service Contact Information Page Network Express Module Overview NEM Features and SpecificationsSee -1for a list of the NEM’s features 5for button locations ID Chip FeatureSystem Interoperability Operating System RequirementsStorage System Support Host Platform SupportFibre Channel Switch Support Hardware Installation and Removal Installing the NEM Observing ESD and Handling PrecautionsTo Install the NEM 1NEM Ejector Levers 2Inserting the NEM Into the Chassis To Connect the Optical Cables 1Optical Cable SpecificationsConnect the other end of each cable to a FC device 2summarizes port LED indicator combinations Using the Ilom Web Interface Configuring the NEM For Hot-Plug OperationShow /CH/NEM1 Using the Ilom Command-Line InterfaceVerifying a Hot-Insert Operation To Verify NEM Status Using the Ilom CLI5LEDs, Attention and Locator Buttons To Install the ID Chip Patch Replacing a NEMTo Remove a NEM 6Location of ID Chip To Replace the ID Chip7Installing the ID Chip Driver Software for the Solaris OS Solaris Diagnostic SupportDriver Software for Linux OSs Red Hat Enterprise LinuxNovell Suse Linux Enterprise Server Run YaST online To Build the Linux 2.6 DriverConfiguration and Diagnostic Utilities To Install Windows OS Driver and Application KitsDriver Software for Windows 2003 OS HBA Software Installation Page Release Notes Using the NEM With Sun StorEdge 3510 and 3511 ArraysSuse Linux Enterprise-Specific Issues Solaris OS-Specific IssuesWindows Server 2003 OS-Specific Issues Out of Option ROM Memory Error in SystemP E N D I X a Page Declaration of Conformity Page Safety Precautions Safety Agency Compliance StatementSystem Unit Cover Power Cord Connection Battery WarningRack System Warning Conformité aux normes de sécuritéCD and DVD Devices Laser Compliance NoticeModification du matériel SymbolesConformité Selv Connexion du cordon d’alimentationMise en garde relative au système en rack Mise en garde relative aux batteries Couvercle de lunitéEinhaltung sicherheitsbehördlicher Vorschriften SymboleAvis de conformité des appareils laser Périphériques CD et DVDAufstellung von Sun-Geräten Modifikationen des GerätsLautstärke SELV-KonformitätWarnung bezüglich Batterien GehäuseabdeckungWarnungen bezüglich in Racks eingebauter Systeme Normativas de seguridad Cumplimiento de la normativa para instalaciones Selv Nivel de ruidoConexión del cable de alimentación Advertencia sobre las bateríasCubierta de la unidad del sistema Nordic Lithium Battery CautionsAdvertencia sobre el sistema en bastidor Dispositivos de CD y DVDSuomi DanmarkRegulatory Compliance Statements FCC Class a NoticeICES-003 Class a Notice Avis NMB-003, Classe a Bsmi Class a Notice D33728Korean MIC Class a Statement CCC Class a NoticePage Index Bios PostNEM