Sun Microsystems SG-XPCIE20FC-NEM-Z manual To Build the Linux 2.6 Driver, Run YaST online

Page 41

2.Run YaST online.

You will be notified that the 8.0.16.27 is being installed.

Note – If you are running on a 2.6.5-7.244 kernel, you must install the Emulex

8.0.16.27 driver manually instead of updating using YaST. The driver RPM is contained on the resource CD.

To Install SLES9-SP3 to FC Disk

Before starting this procedure, you will need to create a driver update disk using the ISO image for driver vesion 8.0.16.27 provided on the Sun Blade 8000 Series Modular Systems resource CD. You can also download the Emulex driver update disk from the Emulex or Novell support web site.

Emulex web site:

http://www.emulex.com/sun/support/nem-e11000.jsp

Novell web site:

http://forgeftp.novell.com/driver- process/pub/update/SUN/sle9/DUD/emulex8.0.16.27/

To update the driver to version 8.0.16.27:

1.Install SLES9-SP3using the normal install process.

2.When prompted for the update disk, load the driver update CD.

3.Continue the installation until all files are installed and the system reboots.

4.After the system reboots, follow the steps described in “To Update the Driver” on page 24.

To Build the Linux 2.6 Driver

You can build your own HBA driver by downloading the archived sources from the Emulex support site.

1.To download the archived sources, go to: http://www.emulex.com/sun/support/nem-e11000.jsp

2.Click the Linux 2.6 Kernel link.

Chapter 3 HBA Software Installation

25

Image 41
Contents For HBA Model SG-XPCIE20FC-NEM-Z Please Recycle Contents HBA Software Installation Contents Page Figures Page Tables Page How This Document Is Organized PrefaceShell Prompts Using Unix CommandsRelated Documentation Typographic ConventionsSun Welcomes Your Comments Documentation, Support, and TrainingThird-Party Web Sites Service Contact Information Page Network Express Module Overview NEM Features and SpecificationsSee -1for a list of the NEM’s features 5for button locations ID Chip FeatureSystem Interoperability Operating System RequirementsStorage System Support Host Platform SupportFibre Channel Switch Support Hardware Installation and Removal Installing the NEM Observing ESD and Handling PrecautionsTo Install the NEM 1NEM Ejector Levers 2Inserting the NEM Into the Chassis To Connect the Optical Cables 1Optical Cable SpecificationsConnect the other end of each cable to a FC device 2summarizes port LED indicator combinations Using the Ilom Web Interface Configuring the NEM For Hot-Plug OperationShow /CH/NEM1 Using the Ilom Command-Line InterfaceVerifying a Hot-Insert Operation To Verify NEM Status Using the Ilom CLI5LEDs, Attention and Locator Buttons To Remove a NEM To Install the ID Chip PatchReplacing a NEM 6Location of ID Chip To Replace the ID Chip7Installing the ID Chip Driver Software for the Solaris OS Solaris Diagnostic SupportNovell Suse Linux Enterprise Server Driver Software for Linux OSsRed Hat Enterprise Linux Run YaST online To Build the Linux 2.6 DriverDriver Software for Windows 2003 OS Configuration and Diagnostic UtilitiesTo Install Windows OS Driver and Application Kits HBA Software Installation Page Release Notes Using the NEM With Sun StorEdge 3510 and 3511 ArraysSuse Linux Enterprise-Specific Issues Solaris OS-Specific IssuesWindows Server 2003 OS-Specific Issues Out of Option ROM Memory Error in SystemP E N D I X a Page Declaration of Conformity Page Safety Precautions Safety Agency Compliance StatementSystem Unit Cover Power Cord Connection Battery WarningRack System Warning Conformité aux normes de sécuritéCD and DVD Devices Laser Compliance NoticeModification du matériel SymbolesConformité Selv Connexion du cordon d’alimentationMise en garde relative au système en rack Mise en garde relative aux batteries Couvercle de lunitéEinhaltung sicherheitsbehördlicher Vorschriften SymboleAvis de conformité des appareils laser Périphériques CD et DVDAufstellung von Sun-Geräten Modifikationen des GerätsLautstärke SELV-KonformitätWarnungen bezüglich in Racks eingebauter Systeme Warnung bezüglich BatterienGehäuseabdeckung Normativas de seguridad Cumplimiento de la normativa para instalaciones Selv Nivel de ruidoConexión del cable de alimentación Advertencia sobre las bateríasCubierta de la unidad del sistema Nordic Lithium Battery CautionsAdvertencia sobre el sistema en bastidor Dispositivos de CD y DVDSuomi DanmarkICES-003 Class a Notice Avis NMB-003, Classe a Regulatory Compliance StatementsFCC Class a Notice Bsmi Class a Notice D33728Korean MIC Class a Statement CCC Class a NoticePage Index Bios PostNEM