Network Technologies SM-nXm-C5AV-LCD operation manual Set Serial Address

Page 16

NTI VEEMUX AUDIO/VIDEO MATRIX SWITCH VIA CAT5

Set Serial Address

When selecting this menu item, the display shows the current serial address and the user is prompted to introduce a new serial address. One or two digits can be entered followed by <Enter>. The display will prompt if the address is successfully changed. Pressing <Esc> will cancel this command. The serial address is used by the RS232 line to send commands. Valid addresses are between 1 and 99. The factory default address is 1.

Figure 14- Set Serial Address from LCD and keypad

Set Serial Speed

When selecting this menu item, the display shows the current serial speed (baud rate) and offers options to change to a different speed:

Figure 15- Set baud rate from LCD and keypad

The current option is highlighted. Move the highlight (by using arrow keys) to the desired speed and press <Enter> to apply. An alternative way is to press the number key that corresponds to desired speed (see Fig. 15).

To exit from this submenu, press <Esc>.

Available speeds are: 1200,2400,4800, and 9600 baud.

Factory default speed is 9600 baud.

Set IP Address

When selecting this menu item, the display shows the current IP address (default factory IP address is 192.168.1.1) and prompts the user to enter a new IP address. A new IP address is entered using number keys and the <*> key for periods. The user must press <Enter> to save the new IP address. If the new address is invalid, the user will be prompted, otherwise the display will indicate that the address was successfully changed.

Figure 16- Set IP Address from LCD and keypad

Set Subnet Mask

When selecting this menu item, the display will show the current subnet mask. A new subnet mask is entered using number keys and the <*> key for periods. The user must press <Enter> to save the new subnet mask. If the new subnet mask is invalid, the user will be prompted, otherwise the display will indicate that the subnet mask was successfully changed.

The default subnet mask is 255.255.255.0. This does not need to be changed for VEEMUX to work. If deemed necessary, the network administrator will change it .

Set Default Gateway

When selecting this menu item, the display will show the current default gateway. A new default gateway mask is entered using number keys and the <*> key for periods. The user must press <Enter> to save the new default gateway. If the new default gateway is invalid, the user will be prompted, otherwise the display will indicate that the default gateway mask was successfully changed.

The factory set default gateway is 192.168.1.0. This does not need to be changed for VEEMUX to work. If deemed necessary, the network administrator will change it .

12

Image 16
Contents SM-nXm-C5AV-LCD Trademark Table of Contents Appendices Introduction MaterialsSupported Web Browsers Materials Supplied with this kitFeatures and Functions Default User Name and PasswordsVeemux Features and Functions Xtendex Features and Functions Xtendex Installation Audio CompatibilityLocal Unit Xtendex not includedConnect Local User Components to Local Unit Remote Unit Connect the Extended Components to the Remote UnitPlug-in and Boot Up Connect the AC adaptersVeemux Installation Attach ST-C5VA-600 Local Unit to VeemuxMaximum total CAT5 cable length cannot exceed 600 feet Using the Veemux Switch Front Panel Interface OverviewConfiguration menu on LCD Keypad ControlSet Serial Address Set Wserver Timeout Command Answer Description RS232 InterfaceNTI Veemux AUDIO/VIDEO Matrix Switch VIA CAT5 Telnet Interface Command Reply DescriptionTelnet 192.168.1.1 Web Interface Web interface WelcomeSwitch Web interface SwitchNTI Veemux AUDIO/VIDEO Matrix Switch VIA CAT5 Setup Pages Web interface SetupVideo Input Names Video Output NamesUpdate Firmware Web interface Update FirmwareUpdate Web Server Change PasswordHelp Logout Web interface LogoutDevice Discovery Tool Device Discovery ToolCAT5 Cable Interconnection Cable Wiring MethodNull Modem Cables Appendix A- Default Settings TroublshootingAppendix Appendix B- General InformationSize In. WxDxH Appendix D- Product DimensionsAppendix E- Rack mounting Instructions Warranty Information Grounding