NTI VEEMUX AUDIO/VIDEO MATRIX SWITCH VIA CAT5
Appendix C- Distances and Resolutions for CAT5/CAT5e and CAT6 Cables
CABLE | DISTANCE (feet) | RESOLUTION |
CAT5/CAT5e (UTP) | 600 | 1024x768 at 60Hz |
CAT5/CAT5e (UTP) | 400 | 1280x1024 at 60Hz |
CAT5/CAT5e (UTP) | 300 | 1600x1200 at 60Hz |
CAT5/CAT5e (UTP) | 100 | 1920x1440 at 60Hz |
CAT6 (UTP) | 300 | 1024x768 at 60Hz |
CAT6 (UTP) | 200 | 1280x1024 at 60Hz |
CAT6 (UTP) | 100 | 1920x1440 at 60Hz |
Appendix D- Product Dimensions
CONFIGURATION | SIZE (In.) WxDxH |
19x12x1.75 | |
19x12x1.75 | |
19x12x1.75 | |
19x12x3.5 | |
19x12x3.5 | |
19x12x3.5 |
Appendix E- Rack mounting Instructions
This NTI switch was designed to be directly mounted to a rack and includes a mounting flange to make attachment easy. Install 4 captive nuts to the rack in locations that line up with the holes (or slots) in the mounting flange on the NTI switch. Then secure the NTI switch to the rack using four 3/16" diameter screws (not provided). Each screw should be of sufficient length to go completely through the NTI mounting flange, rack frame and fully engage all threads in the captive nut. Be sure to tighten all mounting screws securely.
Do not block power supply vents in the NTI switch chassis (if provided) . Be sure to enable adequate airflow in front of and behind the NTI switch.
Attach all cables securely to the switch and where necessary supply adequate means of strain relief for cables.
Rack
|
| Captive |
R NETWORK | 1275 Danner Drive Tel: | Nuts |
TECHNOLOGIES | Aurora Ohio 44212 Fax: | |
NTI INCORPORATED | www.nti1.com |
3/16” Diameter
Screws
Figure 33- Mount Switch to a Rack
28