Sun Microsystems T6320 service manual Ilom

Page 43

FIGURE 2-6ILOM Fault Management

ILOM

Service Required LED

FRU LEDs

FRUID PROMs

Event Logs

Alerts

In ILOM you can view the ILOM logs to see alerts. FIGURE 2-7is a sample of the ILOM web interface. Using the CLI you can type the show /SP/logs/event/list/ command.

FIGURE 2-7Sample Event Log in ILOM Web Interface

ILOM can detect when a fault is no longer present and clears the fault in several ways:

Fault recovery – The system automatically detects that the fault condition is no longer present. ILOM extinguishes the Service Action Required LED and updates the FRU PROM.

Chapter 2 Sun Blade T6320 Server Module Diagnostics 2-17

Image 43
Contents Sun Microsystems, Inc Page Contents Page Replacing Hot-Swappable and Hot-Pluggable Components Safety InformationReplacing Cold-Swappable Components Page XVR-50 Graphics Accelerator SpecificationsHD15 Video Output Port D-6 Checking Device Configuration D-5Index Index-1 Preface Using Unix CommandsTypographic Conventions Accessing Sun DocumentationShell Prompts Module Sun Blade T6320 Server Module Safety and Compliance ManualDocumentation, Support, and Training Third-Party Web SitesSun Welcomes Your Comments Component Overview Sun Blade T6320 Server Module Product Description1Sun Blade T6320 Server Module With Chassis Front View 3Cable Dongle Connectors Insert the connector straight into the server moduleDuring normal system operation 1Sun Blade T6320 Server Module FeaturesConnections SAS/SATA 2Interfaces With the chassis4Field-Replaceable Units 3Sun Blade T6320 Server Module FRU ListHard Drive on Sun Blade T6320 Server Module FRU ListMulticore Processor Information Support for RAID Storage Configurations Sun Blade RAID 0/1 G2 Expansion Module Finding the Serial NumberMAC address Alom CMT example Additional Service Related Information Sun Blade T6320 Server Module Diagnostics Alom CMT CLI Sun Blade T6320 Server Module Diagnostics OverviewSun Blade T6320 Server Module Diagnostics 1Diagnostic Flowchart System LEDs on 1Diagnostic Flowchart ActionsFRU-namedeemed faulty and disabled FB-DIMM Configuration Guidelines Memory Configuration and Fault HandlingSupported FB-DIMMs and Part Numbers Dimm Installation RulesBR1/CH0/D0 BR0/CH0/D0 BR2/CH0/D0 BR3/CH0/D0 3FB-DIMM Installation RulesYou can also use -2to identify the DIMMs you want to remove FB-DIMM Configuration and InstallationTroubleshooting Memory Faults Memory Fault Handling2FB-DIMM Configuration and Installation Front Panel LEDs and Buttons Interpreting System LEDs3LED Behavior and Meaning LEDs have assigned meanings, described in Table4LED Behaviors With Assigned Meanings 5Front Panel Buttons Ethernet Port LEDs Using Ilom for Diagnosis and Repair VerificationIlom Fru at location is OK Using the Ilom Web Interface For Diagnostics8ILOM Login Screen Changing Post Settings With the Ilom Web InterfacePage Displaying System Faults Changing Post Settings With the Ilom CLIType the show command to see the current Post settings 10Fault Management Page Example Viewing Fault Status Using the Ilom Web Interface11Faulted Component ID Window Viewing Fault Status Using the Ilom CLIShow /SYS/MB/VVCORE Displaying the Environmental Status withSun Blade T6320 Server Module Diagnostics Displaying FRU Information Using the Ilom Web Interface to Display FRU Information15Static FRU Information in the Ilom Web Interface Using the CLI to Display FRU InformationShow /SYS/MB At the -prompt, type the show commandSegment TH Controlling How Post Runs Running Post16. This parameter overrides all other 6Parameters Used For Post Configuration16Flowchart of Ilom Variables for Post Configuration Changing Post Parameters Using the Web Interface to Change Post Parameters7describes how the Post settings will execute 7POST Modes and Parameter Settings17Setting Post Parameters With the Ilom Web Interface 18Changing Power Settings with the Ilom Web Interface Type the set command to change the Post parameters Using the CLI to Change Post ParametersShow /HOST/diag Interpret the Post messages Power cycle the server module to run PostPost error messages use the following syntax Interpreting Post MessagesClearing Post Detected Faults 19Enabling Components With the Ilom Web Interface Clearing Faults With the Web InterfaceCd /SYS/MB/CMP0/P32 Clearing Faults With the Ilom CLIReboot the server module Set componentstate=enabledClearing Faults Manually with Ilom Using the Solaris Predictive Self-Healing FeatureClearing Hard Drive Faults # fmdadm faulty Using the fmadm faulty Command# fmdump Using the fmdump CommandFollow the suggested actions to repair the fault Clearing PSH Detected Faults# fmadm faulty Clearing the PSH Fault From the Ilom LogsAfter replacing a faulty FRU, boot the system Clear the fault from all persistent fault recordsLog in as superuser Collecting Information From Solaris OS Files and CommandsSet /SYS/component clearfaultaction=true Checking the Message BufferIf you want to view all logged messages, type this command Managing Components With Automatic System Recovery CommandsType the syslogd command Log in as superuser Type the following commandSYS/component 8ASR CommandsShow /SYS/MB/USB0 Displaying System Components With the show /SYS CommandAn example with no disabled components An example showing a disabled component# pkginfo grep -i vts Checking SunVTS Software Installation9Sample of installed SunVTS Packages Exercising the System With SunVTSSteps for Exercising the System With SunVTS Software Exercising the System Using SunVTS SoftwareEnable the remote display. On the display system, type Where test-systemis the name of the server you plan to test20 SunVTS BI # /opt/SUNWvts/bin/sunvts -display display-system010Useful SunVTS Tests to Run on This Server Start testingOptional Select the test category you want to run Optional Customize individual testsRemove the server module from the modular system chassis Resetting the Password to the Factory DefaultTo Reset the Root Password to the Factory Default Change the root passwordSun Blade T6320 Server Module Diagnostics Page Hot-Plugging a Hard Drive Hot-Pluggable Hard DrivesRemoving a Hard Drive Rules for Hot-PluggingHDD2 HDD0 HDD1 HDD3 2Hard Drive Locations, Release Button, and Latch Replacing a Hard Drive or Installing a New Hard DriveAdding PCI ExpressModules Page Replacing Cold-Swappable Components Safety InformationElectrostatic Discharge Safety Safety SymbolsUsing an Antistatic Wrist Strap Shutting Down the System Common Procedures for Parts ReplacementUsing an Antistatic Mat Required ToolsSave any open files and quit all running programs Using the Ilom Web Interface to Shut Down the Server ModuleLog in as superuser or equivalent Notify affected users1Powering Off the Server Module with the Ilom Web Interface Using the Ilom CLI to Shut Down the Server ModuleSet /SYS/ preparetoremoveaction=true At the Ilom -prompt, type the set /SYS/PS0Set /SYS/LOCATE value=fastblink 2Disconnecting the Cable Dongle 3Removing the Sun Blade T6320 Server Module From the Chassis Open the ejector levers Figure4Stack Five Server Modules or Fewer Removing and Replacing DIMMs This section describes how to remove and replace DIMMsRemoving the DIMMs 6DIMM Locate Button and Dimm LEDs Locate the DIMMs that you want to replace FigureSixteen DIMMs installed FB-DIMM Configuration 8Removing DIMMs Replacing the DIMMsRemoving the Service Processor Removing and Replacing the Service ProcessorVerifying Dimm Installation 9Removing the Service Processor Prom is keyed to ensure proper orientation Replacing the Service ProcessorRemoving and Replacing the Battery on the Service Processor 11Removing the Battery From the Service Processor Replacing the Battery on the Service ProcessorSet /SP/clock datetime=10 Removing the RAID 5 Expansion Module12Removing the RAID Expansion Module Installing the RAID 5 Expansion Module13Replacing the RAID 5 Expansion Module Verifying the RAID 5 Expansion Module InstallationOk show-disks Ok .properties Configuring the RAID 5 Expansion ModuleReturn to the root node by using the unselect-devcommand For details, see Appendix B and Appendix CFor more information, refer to the following documents at Creating a Bootable Array With the RAID 5 Expansion ModuleAdditional Information Removing the RAID 0/1 Expansion Module14Removing the RAID Expansion Module Replacing the RAID 0/1 Expansion Module15Replacing the RAID 0/1 Expansion Module Verifying the RAID 0/1 Expansion Module InstallationReinstalling the Server Module in the Chassis Finishing Component ReplacementReplacing the Cover 17Inserting the Server Module in the Chassis Page 77 kg Physical SpecificationsLbs fully configured Table A-1Exterior DimensionsTemperature -40˚ C to 60˚ C Maximum altitude 40,000 ft System Environmental SpecificationsOperating Temperature and Altitude Non-Operating Temperature and AltitudeFigure A-2Motherboard Block Diagram Motherboard Block DiagramPage P E N D I X B Creating a Bootable Array Task Map About Creating a Bootable Array on a Sparc SystemInstall and connect the HBA and disk drives Modify two locations on the network install server Modifying the Miniroot Directory On the Install Server# cd /cdrom/raidlive/s0/Raidcard To Modify the Miniroot Directory# cp -r SUNWaac installdirpath/Solaris10/Product To Modify the Product Installation DirectoryTo Create a Logical Drive Using a Network Install Server Building a Logical Drive On Which to Install the Solaris OSOk boot net -s # ./arcconf Create 1 Logicaldrive MAX 5 0 2 0 3 0 # cd /opt/StorMan # ./arcconf GetconfigSc shownetwork To Create a Logical Drive Without a Network Install ServerOk boot cdrom Bringing the drive onlineTo Delete a Logical Drive on the REM Run the Create command as shown in the following example# devfsadm # ./arcconf Getconfig 1 LDTo Label the Newly Created Logical Drive # ./arcconf Delete 1 Logicaldrive# format Next Steps# init Additional Information To Prepare to Install the Solaris OS Preparing to Install the Solaris OSComplete the procedures in Appendix B This section contains the following subsection Use the df command to verify the followingApply the HBA driver package, SUNWaac # reboot# cd /cdrom/Solaris10/Product # pkgadd -R /a -d. SUNWaac Next Steps XVR-50 Graphics Accelerator FeaturesTable D-1lists video formats supported by the HD15 port Video FormatsTable D-1XVR-50 Graphics Accelerator HD15 Video Formats Man Pages Sun OpenGL for Solaris SoftwareThis example shows a list of graphics devices displayed Optional Video Output Default Color DepthLog out and then log back in for the change to take effect Checking Device ConfigurationHD15 Video Output Port Host% fbconfig -dev pfb0 -prconfIndex FRU Man page, D-3, D-4Post SYS/MB server module FRU name Index-5
Related manuals
Manual 22 pages 12.42 Kb

T6320 specifications

The Sun Microsystems T6320 is a high-performance server designed to meet the demands of modern data centers and enterprise applications. As part of the Sun Fire series, the T6320 is built for scalability, efficient resource utilization, and reliability, making it an ideal choice for businesses looking to optimize their IT infrastructure.

One of the key features of the T6320 is its support for the UltraSPARC T2 processor architecture. This multicore processor can handle up to eight threads per core, meaning the T6320 can manage up to 64 simultaneous threads. This threading capability is particularly beneficial for virtualization and multi-threaded applications, allowing organizations to maximize the performance of their software while minimizing latency.

The T6320 also comes equipped with a high-speed memory subsystem, supporting up to 256 GB of DDR2 memory. With a memory bandwidth of up to 17 GB/s, the server ensures that data transfer rates do not become a bottleneck, facilitating faster processing and smoother operation for demanding applications. Moreover, the server supports multi-tier storage configurations, enabling organizations to choose the right balance of performance, capacity, and cost.

In terms of connectivity, the T6320 offers multiple gigabit Ethernet ports, creating a resilient network architecture capable of handling the high data loads typical in enterprise environments. Its redundancy features, including hot-swappable components and mirrored disks, further add to its reliability, ensuring continuous service even during maintenance.

The T6320 is built with energy efficiency in mind, minimizing power consumption without compromising performance. This characteristic is increasingly critical for organizations focused on sustainability and cost savings in their energy expenditures.

Additionally, Sun Microsystems has integrated advanced security features into the T6320, such as hardware-based security mechanisms to protect sensitive data and applications. This feature is vital for businesses operating in regulated industries or those that prioritize data integrity.

Finally, the server supports a variety of operating systems, including Solaris, Linux, and various UNIX flavors. This flexibility allows organizations to run their preferred software environments, making the T6320 a versatile option for diverse IT needs.

Overall, the Sun Microsystems T6320 stands out as a powerful, flexible, and efficient server solution, adept at handling the complexities of today's enterprise workloads while paving the way for future growth and technological advancements.