Powering On and Powering Off the Server Module
You have to apply only standby power to the server module at this point so that you can perform initial configuration of the service processor (SP). Procedures for powering on to main power mode and for shutting down from main power mode are also included in this section.
▼To Apply Standby Power for Initial Service Processor Configuration
Use this procedure to apply standby power to the service processor (SP) before initial configuration.
1.Connect grounded AC power cords to the AC power connectors on the back panel of the chassis and to grounded AC power outlets. For details, see your chassis documentation.
In standby power mode, the blue (Ready to Remove) LED is illuminated, indicating that the SP is working. See FIGURE
Note – At this point, standby power is supplied only to the service processor and power supply fans.
2.Continue with initial software setup tasks, as described in Chapter 2 of this guide.
▼To Power on Main Power for All Server Module Components
1.Verify that standby power is on.
In standby power mode, the blue (Ready to Remove) LED is illuminated. See FIGURE
Chapter 1 Setting Up the Server Hardware | 5 |