| supported languages |
|
|
Networking Software | ONC™ , ONC+(TM), NFS(TM), WebNFS(TM), TCP/IP, SunLink™, OSI, |
| MHS, IPX™ /SPX, SMB technologies, and XML |
|
|
Management | CLI |
| |
|
|
Physical Specifications
Description | U.S. | International |
Height | 3.5 inches (2 RU) | 89 mm |
|
|
|
Width | 17.4 inches including bezel | 442 mm including bezel |
| 16.7 inches no including bezel | 424 mm not including bezel |
|
|
|
Depth | 20 inches max depth | 508 mm max depth |
| 19 inches to the connector plane | 483mm to connector plane |
|
|
|
Weight, approximate (without PCI cards or | 35lbs (2 disk version) | 16 kgs (2 disk version) |
rack mounts) | 37.2lbs (4 disk version) | 17 kgs (4 disk version) |
|
|
|
Environment Specifications
These are the environmental specifications for the NetraTM X4200 server.
Specification | Operating | |
Temperature | 5°C to 40°C, (41°F to 104°F) | |
| Short Term |
|
|
|
|
Relative Humidity | 5% to 85% relative humidity, noncondensing | Up to 93% relative humidity |
| Short term: 5% to 90% relative humidity, | noncondensing, 38°C (100.4°F) max |
| noncondensing, but not to exceed 0.024 kg | wet bulb |
| water/kg dry air (0.053 lbs. water/2.205 lb. dry |
|
| air) |
|
|
|
|
Altitude | Up to 3000 meters (9,850 feet) @40°C | Up to 12,000 meters (40,000 feet) |
|
|
|
Power Source Requirements
The Netra X4200 M2 server has two autoranging AC or DC power supplies. To ensure redundant operation of the power supplies, the two power inputs should be connected to separate power sources.
These are the electrical limits and ranges for the Netra X4200 M2 server utilizing 550W power supplies.
Description | AC Specification | DC Specification |
Operating input voltage range | 100 to 240 VAC, 50 to 60 Hz | |
|
|
|
|
|
|
Maximum operating input current | 6.5A at 100 to 120 VAC | 12.7A at |
| 3.2 A at 200 to 240 VAC | 10.2A at |
|
|
|
Maximum heat dissipation | 2150 BTU/hr. | 2085 BTU/hr. |
|
|
|
Just the Facts, August 2007 Sun Confidential: Internal and Sun Channel Partners Use Only | 32 |