Specifications
Table 13 and Table 14 list power supply specifications for the
The standard package Bridge is powered by the included AC adapter. Table 13
Note: and Table 14 do not apply to the standard package.
Table 13. Heavy-Duty Power Supply Specifications
Parameter
Normal Operating (J1455 – 12 V system)
Normal Operating (J1455 – 24 V system)
Cold Cranking (J1211)
Jumper Start 5 minute (J1455 – 12 V system)
Reverse Polarity (J1455 – 24 V system)
Max. Voltage
Min
9V
18V
4.5V
Max
16V
32V
24V
36V
Additional filtering is provided to accommodate the ISO 7637 Power Line Immunity and the SAE J1113 Power Line Conducted Emissions requirements.
Table 14.
Symbol | Parameter | Min | Typ | Max | Units |
|
|
|
|
|
|
VSupply | Supply Voltage | 4.5 |
| 32 | V |
|
|
|
|
|
|
ISupply | Supply Current @ VSupply = 12 V |
| 200 | 350 | mA |
|
|
|
|
|
|
IInrush | Peak Inrush Current For 25 ms |
|
| 2.9 | A |
|
|
|
|
|
|
Page 58 | AirborneDirect™ Ethernet Bridge User's Guide |