Patton electronic 1092A Using the V.52 BER Test Pattern Generator, Appendix a, Weight Lbs .0kg

Page 16
Two or Four-Wire unconditioned twisted pair Internal, external or receive loopback
EIA RS-232/ITU/T V.24, RS-232/530, ITU/T V.35, ITU/T X.21, 64k G.703, 10BaseT Ethernet, and Voice/Data
Synchronous 19, 2, 32, 56, 64 & 128 kbps; Asynchronous0 - 38.4 kbps
V.52 compliant bit error rate pattern (511/511E pattern) generator and detector with error injection mode; Local Line Loopback and Remote Digital Loopback, activated by front panel switch or via serial interface
TD, RD, CTS, CD, DTR, NS(no signal), ER (error) and TM (test mode)
RJ-45 on line side; DB-25 female, M/34 female or DB-15 female on serial interface side, depending upon which interface module is installed.
100-253 VAC, 50-60 Hz (universal input); 48 VDC (option). 10 watts.
Synchronous or asynchronous

5.3.3 Using the V.52 (BER) Test Pattern Generator

To use the V.52 BER tests in conjunction with the Remote Digital Loopback tests (or with Local Line Loopback tests), follow these instructions:

1.Locate the “511/511E” toggle switch on the front panel of the 1092A and move it UP. This activates the V.52 BER test mode and transmits a “511” test pattern into the loop. If any errors are present, the local modem’s red “ER” LED will blink sporadically.

2.If the above test indicates no errors are present, move the

V.52 toggle switch DOWN, activating the “511/E” test with errors present. If the test is working properly, the local modem's red “ER” LED will glow. A successful “511/E” test will confirm that the link is in place, and that the Model 1092A’s built-in “511” generator and detector are working properly.

APPENDIX A

PATTON ELECTRONICS MODEL 1092A SPECIFICATIONS Transmission Format:

Transmission Line:

Clocking:

Interface Modules:

Data Rates:

Diagnostics:

LED Status Indicators:

Connectors:

Power:

Temperature Range:

32-122°F (0° -50°C)

 

 

Altitude:

0-15,000 feet

 

 

 

Humidity:

5 to 95% non-condensing

 

 

Dimensions:

7.3” x 6.6” x 1.62” (185mm x 168mm x 41mm)

Weight:

2.01 lbs. (1.0kg)

 

 

 

 

 

 

 

 

 

 

 

 

 

2-Wire Distance Table in miles (km)

 

 

 

 

 

 

 

 

 

 

 

Data

 

 

AWG Wire Gauge (mm)

 

 

Rate

 

 

 

 

 

 

 

 

19(.9)

22(.6)

24(.5)

6(.4)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

All Rates

 

10.8(17.2)

7.2(11.5)

5.0(8.0)

3.4 (5.5)

 

 

 

 

 

 

 

 

 

 

4-Wire Distance Table in miles (km)

 

 

 

 

 

 

 

 

 

 

Data

 

 

Wire Gauge

 

 

 

Rate

 

 

 

 

 

 

 

 

19(.9)

22(.6)

24(.5)

6(.4)

 

 

 

 

 

 

 

 

 

 

All Rates

 

11.4(18.2)

7.6(12.1)

5.3(8.5)

3.6(5.7)

 

29

30

Image 16
Contents User Manual Table of Contents Warranty InformationRadio and TV Interference CE NoticeService FeaturesGeneral Information Description1092A Snmp Management Solutions ConfigurationConfiguring the Hardware DIP Switches HTTP/HTML ManagementS1 Summary Table S2 Summary Table Configuring the Local 1092A Configuring the Software SwitchesMain Menu Option 1 Display Active Configuration Main Menu Option 3 Display Software Configuration Main Menu Option 2 Display Hardware ConfigurationMain Menu Option 4 Setup Software Configuration Data Format Main Menu Option 6 Display Modem Status DTE Controlled Remote Digital LoopMain Menu Option 7 Test Modes Connecting the Twisted Pair Interface InstallationOFF Signal PIN# Signal PIN# Connecting the Serial PortInstalling the New QuikConnect Module Changing QuikConnect ModulesConnecting to a DTE Device Connecting to a DCE DeviceConfiguring the X.21 QuikConnect Module Connecting PowerPOWER-UP LED Status MonitorsTD & RD CTSLocal Line Loopback LLB Test ModesRemote Digital Loopback RDL Weight Lbs .0kg Using the V.52 BER Test Pattern GeneratorAppendix a Patton Electronics Model # Description IM1/JSInterface 34F Female Connector DCE Configuration Interface DB-15 Female Connector DTE /DCE ConfigurationMaster Unit Settings Appendix E Patton Electronics Model 1092A Quick Start Guide