Patton electronic user manual Appendix E Patton Electronics Model 1092A Quick Start Guide

Page 19

APPENDIX D

PATTON ELECTRONICS MODEL 1092A

CONTROL PORT PIN ASSIGNMENT

The 1092A control port is an 8 position connector, compliant with EIA/TIA-561.

Pin Function

RJ45 Pin No.

Ground

4

Receive data (to DTE)

5

Transmit data (from DTE)

6

35

APPENDIX E

PATTON ELECTRONICS MODEL 1092A

QUICK START GUIDE

1)To perform a hardware reset, turn the power off and set configuration switch (S1-6 and 7 “OFF").

2)Turn on the power for 5 or 10 seconds. Turn the power OFF and re-configure the model 1092A using the following configuration. One unit must be set as Master the other unit as Slave.

MASTER UNIT SETTINGS

S1-1 "ON"

S1-2 "OFF"

S1-3 "ON"

S1-4 and 5 "OFF"

S1-6 and 7 "ON"

S1-8 "ON"

S2-1, 2, and 3 "OFF"

S2-4 "ON" (4-wire operation) "OFF" (2-wire operation)

S2-5 "OFF"

S2-6, 7 and 8 "ON"

SLAVE UNIT SETTINGS

S1-1 "ON"

S1-2 "OFF"

S1-3 "ON"

S1-4 and 5 "OFF"

S1-6 "ON"

S1-7 "OFF"

S1-8 "ON"

Switch S2 settings are the same as the MASTER UNIT.

3)Connect the twisted pair circuit between the model 1092A's, turn on the power, after 10 to 15 seconds the NS (no signal)- LED will go off and the CD (carrier detect) LED will turn GREEN.

4)Perform a LOCAL LINE LOOP-BACK test using the 511/511E test switch (See section 5.3.1).

5)Approximately 45 seconds after the units link up, perform a REMOTE DIGITAL LOOP-BACK test using the 511/511E test switch. (See section 5.3.2).

Copyright © 2000

Patton Electronics Company

All Rights Reserved

36

Image 19
Contents User Manual CE Notice Table of ContentsWarranty Information Radio and TV InterferenceDescription ServiceFeatures General InformationHTTP/HTML Management 1092A Snmp Management SolutionsConfiguration Configuring the Hardware DIP SwitchesS1 Summary Table S2 Summary Table Configuring the Local 1092A Configuring the Software SwitchesMain Menu Option 1 Display Active Configuration Main Menu Option 3 Display Software Configuration Main Menu Option 2 Display Hardware ConfigurationMain Menu Option 4 Setup Software Configuration Data Format Main Menu Option 6 Display Modem Status DTE Controlled Remote Digital LoopMain Menu Option 7 Test Modes Connecting the Twisted Pair Interface InstallationOFF Changing QuikConnect Modules Signal PIN#Signal PIN# Connecting the Serial Port Installing the New QuikConnect ModuleConnecting Power Connecting to a DTE DeviceConnecting to a DCE Device Configuring the X.21 QuikConnect ModuleCTS POWER-UPLED Status Monitors TD & RDLocal Line Loopback LLB Test ModesRemote Digital Loopback RDL Weight Lbs .0kg Using the V.52 BER Test Pattern GeneratorAppendix a IM1/JS Patton Electronics Model # DescriptionInterface DB-15 Female Connector DTE /DCE Configuration Interface 34F Female Connector DCE ConfigurationAppendix E Patton Electronics Model 1092A Quick Start Guide Master Unit Settings