3.1.1 Configuration DIP Switch Set “S1”

Use the eight switches in DIP Switch Set “S1” to configure the data rate, asynchronous or synchronous data format, transmit clock source and response to RDL request. The following table summarizes default positions of DIP Switch S1. Detailed descriptions of each switch follow the table.

S1 SUMMARY TABLE

Position

Function

Factory Default

 

 

 

 

 

 

 

S1-1

Data Rate

On

}

64K Sync

S1-2

Data Rate

Off

 

 

 

 

 

 

S1-3

DSR during Local Line Loop

On

 

DSR On

 

 

 

S1-4

SNMP Management

Off VT100 Mgmt

 

S1-5

Reserved

Off

 

 

 

 

 

 

 

 

 

 

 

S1-6

Tx Clock Source

On

}

Internal Clock

S1-7

Tx Clock Source

On

 

 

 

 

 

 

S1-8

Response to RDL Request

On

 

Enable

 

 

 

 

 

 

 

 

 

Switches S1-1 and S1-2: Data Rate

Use Switches S1-1 and S1-2 with Switch S2-1to configure the Async or Sync bit rate for Model 1092A. The following table summarizes default positions of DIP Switch S2. Detailed descriptions of each switch follow the table.

Possible Bit Rate Settings - Switch S1-1, S1-2 and S2-1

S1-1

S1-2

S2-1

Sync Data Rate

Async Data Rate

On

On

Off

32 kbps

Reserved

Off

On

Off

56 kbps

Reserved

On

Off

Off

64 kbps

Reserved

Off

Off

Off

128 kbps

0-38.4 kbps

On

ON

On

Reserved

Reserved

Off

On

On

Reserved

Reserved

On

Off

On

Reserved

Reserved

Off

Off

On

19.2 kbps

Reserved

 

 

 

 

 

Switch S1-3: Data Set Ready During Line Loopback Test

Use Switch S1-3 to control the behavior of the DSR signal at the EIA interface during the line loopback test.

S-3

Setting

On

DSR is on during local line loop

Off

DSR is off during local line loop

Switches S1-4: Management Setting

When setting the 1092A to SNMP Management, the DTE rate switches (S1-1, S1-2, and S2-1) are also needed to be at the ON position. Therefore, to set a 1092A unit SNMP management mode, the following switches have to be at the ON position, S1-1, S1-2, S2-1, and S1-4.

Use Switch S1-4 to configure the 1092A’s management setting.

S1-4

Setting

On

SNMP Management

Off

Control Port Management

Switches S1-5: Reserved

Always at off position

Switches S1-6 and S1-7: System Clock Mode

Use Switches S1-6 and S1-7 to configure the 1092A for internal, external, or receive recover clock mode.

S1-6

S1-7

Clock Mode

Description

On

On

Internal

System clock

 

 

 

generated internally

Off

On

External (DTE)

System clock derived

 

 

 

from terminal interface

On

Off

Receive Recover

System clock derived

 

 

 

from the received line

 

 

 

signal.

Off

Off

Hardware Reset

Reset to use hardware

 

 

 

switches for

 

 

 

configuration

7

8

Image 5
Contents User Manual Warranty Information Table of ContentsRadio and TV Interference CE NoticeFeatures ServiceGeneral Information DescriptionConfiguration 1092A Snmp Management SolutionsConfiguring the Hardware DIP Switches HTTP/HTML ManagementS1 Summary Table S2 Summary Table Main Menu Option 1 Display Active Configuration Configuring the Software SwitchesConfiguring the Local 1092A Main Menu Option 4 Setup Software Configuration Main Menu Option 2 Display Hardware ConfigurationMain Menu Option 3 Display Software Configuration Data Format Main Menu Option 7 Test Modes DTE Controlled Remote Digital LoopMain Menu Option 6 Display Modem Status OFF InstallationConnecting the Twisted Pair Interface Signal PIN# Connecting the Serial Port Signal PIN#Installing the New QuikConnect Module Changing QuikConnect ModulesConnecting to a DCE Device Connecting to a DTE DeviceConfiguring the X.21 QuikConnect Module Connecting PowerLED Status Monitors POWER-UPTD & RD CTSRemote Digital Loopback RDL Test ModesLocal Line Loopback LLB Appendix a Using the V.52 BER Test Pattern GeneratorWeight Lbs .0kg IM1/JS Patton Electronics Model # DescriptionInterface DB-15 Female Connector DTE /DCE Configuration Interface 34F Female Connector DCE ConfigurationAppendix E Patton Electronics Model 1092A Quick Start Guide Master Unit Settings