Patton electronic 2158 Appendix a, LAN Connection, Transmission Line, Copperlink Line Rate

Page 21

APPENDIX A

SPECIFICATIONS

A.1 LAN CONNECTION

Shielded RJ-45, 10/100Base-T, IEEE 802.3 Ethernet

CopperLink Connection: RJ-45 and Terminal Block

A.2 TRANSMISSION LINE

Two-wire unconditioned twisted pair.

A.3 COPPERLINK LINE RATE

Model 2168—16.67 Mbps, symmetric upstream/downstream. Additional symmetric and asymmetric rates are available via DIP switch settings.

Model 2158—Fixed 12.5 Mbps, symmetric upstream/downstream.

A.4 COPPERLINK DISTANCE

6,000 ft (1.83 km) at 1.56 Mbps upstream/4.17 Mbps downstream

Note Distances depend on selected line rate.

A.5 COPPERLINK SURGE SUPPRESSOR

Gas tube with maximum current surge: 20 kA (8120 s).

A.6 LED STATUS INDICATORS

Power (Green)

CopperLink: Link (Green) & QOL (Red)

Ethernet: Link (Green), Collision (Yellow), Duplex (Yellow), 10/100M (Yellow), Transmit (Yellow), and Receive (Yellow)

A.7 POWER SUPPLY

Input power: 5 VDC, 1A

Power consumption: 450 mA at 5 VDC

External AC and DC options:

AC: 120 VAC, 220 VAC, and UI (120–240 VAC)

DC: 12 VDC, 24 VDC and 48 VDC

21

Image 21
Contents User Manual Contents CopperLink Series Interface Pin Assignment Distance Chart, Based on 24 AWG 0.5 MMWarranty Information Radio and TV InterferenceCE Notice Tel +1 301 Email support@patton.com ServiceFeatures General InformationDescription Typical application Standalone Unit Installation InstallationCopperLink Ethernet Extender rack cards Rack Card InstallationConnecting the TWISTED-PAIR Line Interface CopperLink Ethernet Extender twisted pair line interface Connecting the 10/100BASE-T Ethernet InterfaceConnecting the 10/100Base-T Ethernet Port to a PC DTE Connecting the 10/100Base-T Ethernet Port to a HubConnecting Power 10/100Base-T DTEPage Configuring the Hardware DIP Switches Configuration Model 2168 onlyModel 2168 standalone modem DIP switch orientation Switch S1-1 Ethernet Auto Sense Configuring DIP Switch S1S1-1 Setting Switches S1-2 and S1-4 Data RateS1-5 S1-6 S1-7 S1-8 Reserved for future use S1-2 S1-3 S1-4 Asymmetric Line Rates DS/USPower UP OperationFront Panel LED Status Monitors LED DescriptionLED is solid yellow and the CopperLink Link LED Port. The more error corrections, the more often Power Supply LED Status IndicatorsAppendix a LAN ConnectionTemperature Range DimensionsHumidity Patton Model # Description Appendix BAppendix C 10/100BASE-T Interface Appendix DRJ-45 Copperlink InterfaceAppendix E Symm Line Rate DS/US Distance in feet kmAsymm Line Rate DS/US Distance in feet km Page Copyright Patton Electronics Company All Rights Reserved