Patton electronic 2158 user manual Rack Card Installation, CopperLink Ethernet Extender rack cards

Page 9

3.2 RACK CARD INSTALLATION

The CopperLink Ethernet Extender rack card comprised a front card and a rear card.Do the following to install the cards into the rack chassis:

1.Slide the rear card into the back of the chassis along the metal rails.

2.Secure the rear card using the supplied metal screws.

3.Slide the front card into the chassis until you feel resistance as the front card engages the rear card. When that happens, gently push the front card forward until it is fully seated in the card-edge recepta- cle of the rear card (it should click into place).

4.Secure the front card using the captive fasteners.

Note The Model 1001R14 chassis supports “hot swapping” of cards, so it is not necessary to power down the rack when you install or remove a CopperLink Ethernet Extender rack card.

Figure 3. CopperLink Ethernet Extender rack cards

5.Connect the line interface between the units (refer to section 3.3, “Connecting the Twisted-Pair Line Interface” on page 10)

Note See Figure 3 for the rack card’s panel arrangements.

9

Image 9
Contents User Manual Contents CopperLink Series Interface Pin Assignment Distance Chart, Based on 24 AWG 0.5 MMWarranty Information Radio and TV InterferenceCE Notice Tel +1 301 Email support@patton.com ServiceFeatures General InformationDescription Typical application Standalone Unit Installation InstallationCopperLink Ethernet Extender rack cards Rack Card InstallationConnecting the TWISTED-PAIR Line Interface CopperLink Ethernet Extender twisted pair line interface Connecting the 10/100BASE-T Ethernet InterfaceConnecting the 10/100Base-T Ethernet Port to a PC DTE Connecting the 10/100Base-T Ethernet Port to a HubConnecting Power 10/100Base-T DTEPage Configuring the Hardware DIP Switches Configuration Model 2168 onlyModel 2168 standalone modem DIP switch orientation Switch S1-1 Ethernet Auto Sense Configuring DIP Switch S1S1-1 Setting Switches S1-2 and S1-4 Data RateS1-5 S1-6 S1-7 S1-8 Reserved for future use S1-2 S1-3 S1-4 Asymmetric Line Rates DS/USPower UP OperationFront Panel LED Status Monitors LED DescriptionLED is solid yellow and the CopperLink Link LED Port. The more error corrections, the more often Power Supply LED Status IndicatorsAppendix a LAN ConnectionTemperature Range DimensionsHumidity Patton Model # Description Appendix BAppendix C 10/100BASE-T Interface Appendix DRJ-45 Copperlink InterfaceAppendix E Symm Line Rate DS/US Distance in feet kmAsymm Line Rate DS/US Distance in feet km Page Copyright Patton Electronics Company All Rights Reserved