Patton electronic 1095 user manual Loops and Patterns, Local Loop, With 511/511E

Page 14

5.3.2 Loops and Patterns

The following section describes the Test Modes used in the Model 1095. At the bottom of each Test Mode, a figure is included to show the data path.

Local Loop

There are two different modes of operation for a

Framer

Pattern

Loop

 

Gen/Det

Control

 

Processor

Line

Loop Pattern

Control Gen/Det

Processor

Framer

Local Loop depending on the status of the units

at the time that the Local Loop is initiated. If the

Figure 8. Block Diagram Local Loop Mode 1

units are not in linked (NS LED on) and the

Local Loop is initiated, either by the front panel

switch or the DTE interface, the unit will enter

mode 1. If the units are linked, NS LED off, then

the unit will enter a mode 2 Local Loop.

A Mode 1 Local Loop is shown in Figure 7.

When the Local Loop is initiated, either by the

Framer

Pattern

Loop Control

Line

Loop Control

Pattern

Framer

Gen/Det

 

Gen/Det

 

 

 

 

 

Processor

 

Processor

 

 

front panel switch or the DTE interface, the loop

will be activated within the local Processor. The

data present at the local DTE interface will be

looped back to the local DTE by the Loop

Control block within the Processor. Any data

present on the line or at the far end DTE inter-

face is invalid. The remote unit will remain in the

StartUP mode, NS LED on, CTS LED yellow,

and CD LED yellow, until the local unit is taken

out of the Local Loop mode. After the Local

Loop is deselected, the units will both be in

StartUP mode and the link will be established.

A mode 2 Local Loop is shown in Figure 8.

When the Local Loop is initiated, either by the

front panel switch or the DTE interface, two sep-

arate loop paths will be started. In the first path,

data presented to the local DTE interface will be

looped back to the local DTE within the framer.

In the second path, data presented at the far

end DTE will be transmitted to the local DTE

and then looped back within the local DTE Loop

Control block with the Processor. After the Local

Loop is deselected, the units will be placed back

into DataMode and the normal data paths will

be re-established.

25

 

Figure 9. Block Diagram Local Loop Mode 2

Local Loop

When the unit is placed into a Mode 1. Local

with 511/511E

Loop and the 511/511E pattern generator is

 

activated, the local pattern generator begins

 

sending out a 511/511E pattern to the Loop

 

Control block. The Loop Control block will loop

 

this data back to the 511/511E pattern detector

 

block, which will evaluate the data for errors.

 

Because the 511/511E pattern generator is con-

 

tained within the Processor the data is unframed

 

so the framer will begin seeing unframed pack-

 

ets. The framer receives this unframed data and

 

can not distinguish this information from a line

 

disconnection (this would cause the units'

 

Restart procedure to start). What we have done

 

to allow this mode to work is to add time outs for

 

the pattern generators. When the 511/511E is

 

initiated, the line restart procedure is changed to

 

one minute. The 511/511E pattern will timeout

 

after 45 seconds. So if the 511/511E is turned

 

on during a local loop, the restart procedure is

 

set to one minute, but the 511/511E pattern will

 

time out after 45 seconds, allowing the framer to

 

begin seeing framed packets (and not restart

 

the box).

 

26

Image 14
Contents User Manual CE Notice SectionRadio and TV Interference Tel Email support@patton.com ServiceFeatures DescriptionConfiguring the Hardware DIP Switches Configuration DIP Switch Set S2CO/CP S3 Summary TableConfiguring the Software Switches Main Menu Screen VT100 Terminal ConfigurationSoftware Configuration Menu Option #1 DTE RateExiting the Configuration Mode Option #2 Clock Mode Selection MenuOption #6 CO/CP Mode Option #3 DTE Interface TypeConnecting the Twisted Pair Interface Netlink PLUG-AND-PLAYConnecting the Serial Port Connecting to a DC Power Source Configuring the X.21 QuikConnect ModuleConnecting Power TD & RD POWER-UPLED Status Monitors CTSFramer Restart ProcedureSymbol Indicators Pattern Gen/DetWith 511/511E Loops and PatternsLocal Loop Remote Digital LoopLoop with 511/511EPatton Electronics Model Specifications Patton Electronics Model # Description Patton Electronics Model 1095 Interface PIN AssignmentDB-15 Female Connector 34F Female ConnectorPin # Signal DTE /DCE ConfigurationAppendix E LED Descriptions