5.3.3 Using the V.52 (BER) Test Pattern Generator

To use the V.52 BER tests in conjunction with the Remote Digital Loopback tests (or with Local Line Loopback tests), follow these instructions:

1.Locate the “511/511E” toggle switch on the front panel of the 1095 and move it DOWN. This activates the V.52 BER test mode and transmits a “511” test pattern into the loop. If any errors are present, the local modem’s red “ER” LED will blink sporadically.

2.If the above test indicates no errors are present, move the V.52 toggle switch UP, activating the “511/E” test with errors present. If the test is working properly, the local modem's red “ER” LED will blink. A successful “511/E” test will confirm that the link is in place, and that the Model 1095’s built-in “511” generator and detector are working properly.

NOTE: The above V.52 BER tests can be used independently of the Remote Digital Loopback tests. This requires two operators:

(1)to initiate and monitor the tests at the local Model 1095, and

(2)to do the same at the remote Model 1095. In this case, the test pattern sent by each Model 1095 will not be looped back, but will be transmitted down the line to the other Model 1095. While one operator initiates test, the other monitors for errors.

31

APPENDIX A

PATTON ELECTRONICS MODEL 1095

SPECIFICATIONS

Transmission Format:

Synchronous

Transmission Line:

Two-Wire unconditioned twisted pair

Clocking:

Internal, external or receive recovered clock

Interface Modules:

EIA RS-232/ITU/T V.24, RS-232/530,

 

ITU/T V.35 and ITU/T X.21

Line Rates:

144, 272, 400, 528, 784, 1040, 1552,

 

2064, and 2320 kbps

DTE Rates:

64, 128, 192, 256, 320, 384,448, 512, 576,

 

640, 704, 768, 832, 896, 960, 1024, 1088,

 

1152, 1216, 1280, 1344,1408, 1472, 1536,

 

1544, 1600, 1664, 172, 1792, 1856, 1920,

 

1984, 2048, 2112, 2176, 2240, and 2304 kbps

Diagnostics:

V.52 compliant bit error rate pattern

 

(511/511E pattern) generator and detector

 

with error injection mode; Local Line

 

Loopback and Remote Digital Loopback,

 

activated by front panel switch or via serial

 

interface

LED Status Indicators:

TD, RD, CTS, CD, DTR, NS(no signal), ER

 

(error) and TM (test mode)

Connectors:

RJ-45 on line side; DB-25 female, M/34

 

female or DB-15 female depending upon

 

which serial interface module is installed.

Power:

100-253 VAC, 50-60 Hz (universal input);

 

48 VDC (option), 10 watts.

Line Protection:

Surge Arrestor standard on all units

Temperature Range:

32-122°F (0° -50°C)

Altitude:

0-15,000 feet

Humidity:

5 to 95% non-condensing

Dimensions:

7.3” x 6.6” x 1.62” (185mm x 168mm x 41mm

Weight:

2.01 lbs. (1.0kg)

 

32

Image 17
Contents User Manual CE Notice SectionRadio and TV Interference Features ServiceTel Email support@patton.com DescriptionConfiguration DIP Switch Set S2 Configuring the Hardware DIP SwitchesS3 Summary Table CO/CPConfiguring the Software Switches Software Configuration Menu VT100 Terminal ConfigurationMain Menu Screen Option #1 DTE RateOption #6 CO/CP Mode Option #2 Clock Mode Selection MenuExiting the Configuration Mode Option #3 DTE Interface TypeNetlink PLUG-AND-PLAY Connecting the Twisted Pair InterfaceConnecting the Serial Port Connecting to a DC Power Source Configuring the X.21 QuikConnect ModuleConnecting Power LED Status Monitors POWER-UPTD & RD CTSSymbol Indicators Restart ProcedureFramer Pattern Gen/DetWith 511/511E Loops and PatternsLocal Loop Loop Remote Digital511/511E Loop withPatton Electronics Model Specifications Patton Electronics Model 1095 Interface PIN Assignment Patton Electronics Model # DescriptionPin # Signal 34F Female ConnectorDB-15 Female Connector DTE /DCE ConfigurationAppendix E LED Descriptions