3.3CONNECTING THE TWISTED-PAIR LINE INTERFACE

The Model 1068 supports communication between two peer Ethernet LAN sites over a distance of up to 6,652 ft (2.03 km) over 24 AWG (0.5 mm) twisted-pair wire.

Note Actual distance and link performance may vary depending on the environment and type/gauge of wire used.

Follow the steps below to connect the Model 1068 VDSL Interfaces.

Note The Model 1068 units work in pairs. One of the units must be a Model 1068/CO (Central Office), and the other unit must be a Model 1068/CP (Customer Premise). It does not matter which end is the 1068/CO and which is the 1068/CP. The link is always initiated by the 1068/CP. As long as the 1068/CO is powered on, the 1068/CP can establish a link by being powered on or by hav- ing its power reset.

1.To function properly, the two Model 1068s must be connected together using twisted-pair, unconditioned, dry, metal wire, between 19 (0.9mm) and 26 AWG (0.4mm). Leased circuits that run through signal equalization equipment are not acceptable.

2.The Model 1068 is equipped with two interface jacks that can be used on the VDSL interface, an RJ-45 or a terminal block. These VDSL interfaces are a two-wire interface. Observe the signal/pin relation- ships on the Model 1068's VDSL interface jacks.

The RJ-45 connector on the Model 1068's twisted pair interface is polar- ity insensitive and is wired for a two-wire interface. The signal/pin rela- tionship is shown in Figure 4.

 

1 (no connection)

1

2 (no connection)

23 (no connection)

4

4

(2-Wire RING)

 

 

5

5

(2-Wire TIP)

6

6 (no connection)

7

7 (no connection)

8

8 (no connection)

Figure 4. Model 1068 (RJ-45) twisted pair line interface.

11

Image 11
Contents User Manual Contents Distance CHART, Based on 24 AWG 0.5 MM CE Notice Warranty InformationRadio and TV Interference Page Tel +1 301 Email support@patton.com Industry Canada Notice ServiceDescription FeaturesGeneral Information Typical application 1068DV InstallationStandalone Unit Installation 1068DVRC 1068DRC Rack Card InstallationModel 1068 RJ-45 twisted pair line interface Connecting the TWISTED-PAIR Line InterfaceModel 1068D Terminal Block twisted pair line interface Connecting the 10/100BASE-T Ethernet Interface1068 10/100Base-T Port 10/100Base-T Hub RJ-45 Pin No Connecting the 10/100Base-T Ethernet Port to a HubConnecting the 10/100Base-T Ethernet Port to a PC DTE Connecting the POTS/ISDN LineModel 1068DV RJ-45 POTS/ISDN interface Connecting PowerConfiguring the Hardware DIP Switches ConfigurationSwitch toggle Configuring DIP Switch S1 Asymmetric Line Rates DS/US S1-2Front Panel LED Status Monitors Power UPOperation Description LEDDimensions LED Status IndicatorsPower Supply Temperature RangePatton Model # Description Appendix BPOTS/ISDN Interface Appendix C10/100BASE-T Interface Vdsl InterfaceAsymm Line Rate DS/US Distance in feet km Appendix DSymm Line Rate DS/US Distance in feet km