Patton electronic user manual Configuration Switch SET S1, Model 1065 S1 Summary Table

Page 4

The Model 1065 SRM has three sets of eight switches, yielding 24 total DIP switches. The three sets will be referred to as S1, S2 and

S3. As Figure 2 shows, the orientation of all DIP switches is the same with respect to “ON” and “OFF” positions.

ON

OFF

Figure 2. Close-up of DIP switches showing “ON” and “OFF” positions

3.2 CONFIGURATION SWITCH SET “S1”

The DIP switches on S1 set data rate, clock source, async./sync. mode and carrier control method. The default settings are summarized in the table below.

MODEL 1065 S1 SUMMARY TABLE

Position

Function

 

Factory Default

 

 

 

 

 

 

 

S1-1

Data Rate

On

}

 

 

S1-2

Data Rate

Off

9,600 bps

 

 

 

 

 

S1-3

Data Rate

Off

 

 

S1-4

Data Rate

On

 

 

S1-5

Clock Source

On

}

Internal

 

S1-6

Clock Source

On

 

S1-7

Async./Sync.

On

 

Async.

 

 

 

 

 

 

 

S1-8

Carrier Control

Off

 

Constantly On

 

 

 

 

 

 

 

Switches S1-1 through S1-4 & S3-3: Data Rate Setting

Switches S1-1, S1-4, and S3-3 are set in combination to deter- mine the asynchronous and synchronous data rate for the Model 1065.

Shown in the tables below are DIP Switch settings for Models 1065.

 

 

MODEL 1065 DATA RATE SETTINGS

 

 

 

 

S1-1

S1-2

S1-3

S1-4

S3-3

Setting

 

 

 

On

On

On

On

Off

1.2 kbps

 

 

 

Off

On

On

On

Off

1.8 kbps

 

 

 

On

Off

On

On

Off

2.4 kbps

 

 

 

Off

Off

On

On

Off

3.6 kbps

 

 

 

On

On

Off

On

Off

4.8 kbps

 

 

 

Off

On

Off

On

Off

7.2 kbps

 

 

 

On

Off

Off

On

Off

9.6 kbps

 

 

 

Off

Off

Off

On

Off

14.4 kbps

 

 

 

Off

On

Off

On

On

16.0 kbps

 

*

 

On

On

On

Off

Off

19.2 kbps

 

 

 

 

 

Off

On

On

Off

Off

28.8 kbps

 

 

 

Off

Off

Off

On

On

32.0 kbps

 

*

 

On

On

Off

Off

Off

38.4 kbps

 

 

 

 

 

Off

On

Off

Off

Off

57.6 kbps

 

 

 

Off

On

On

Off

On

64.0 kbps

 

*

*Must have switch 3-3 On

Switches S1-5 and S1-6: Clock Source

Switches S1-5 and S1-6 are set in combination to determine the transmit clock source for the Model 1065 Series.

S1-5

S1-6

Setting

On

On

Internal transmit clock

Off

On

Receive recover clock

On

Off

External transmit clock

Switch S1-7: Asynchronous/Synchronous Mode

The setting for switch S1-7 determines whether the Model 1065 Series is in asynchronous or synchronous operating mode.

S1-7

Setting

On

Asynchronous

Off

Synchronous

5

6

Image 4
Contents User Manual Radio and TV Interference ServiceTel 301 Configuration Switches FeaturesDescription Model 1065 Data Rate Settings Configuration Switch SET S1Model 1065 S1 Summary Table Configuration Switch SET S2 S2 Summary TableS3 Summary Table Configuration Switch SET S3S3-1, S3-2 Selection Table for Model Switch S3-5 RS-232 Initiation of Local Loopback Test Switch S3-6 RS-232 Initiation of Remote Loopback TestSwitches S3-7 and S3-8 Anti-stream Control TWO-WIRE InstallationTwo-Wire Cable Connection Via RJ-45 RJ-45 SignalSignal PIN# Color FOUR-WIRE InstallationMultipoint Twisted Pair Connection FOUR-WIRE, Multipoint InstallationRS-232 Connection ANTI-STREAMING Error Indicator LED Status MonitorsPOWER-UP Using the V.52 BER Test IndependentlyV.54 Test Modes Local Analog Loopback LALPOWER-DOWN Appendix a Patton Electroniics Model 1065 SpecificationsPatton Model # Description Appendix C Patton Electronics Model Cable Recommendations