Switch S1-8: Carrier Control Method

The setting for switch S1-8 determines whether the carrier is “con- stantly on” or “controlled by RTS”. This setting allows for operation in switched carrier, multipoint and/or hardware handshaking applications.

S1-8

Setting

Off

Constantly on

On

Controlled by RTS

3.3 CONFIGURATION SWITCH SET “S2”

The DIP switches on S2 set word length, extended signaling rate, RTS/CTS delay, V.52 and V.54 diagnostic test and 2- and 4-wire opera- tion.

S2 SUMMARY TABLE

Position

Function

Factory Default

 

 

 

 

 

S2-1

Word Length

Off

} 10 bits

S2-2

Word Length

Off

 

 

 

 

 

S2-3

Extended Signaling Rate

Off

-2.5% to 1%

 

 

 

 

 

S2-4

RTS/CTS Delay

On

} 7 ms

S2-5

RTS/CTS Delay

On

 

 

 

 

 

S2-6

2-Wire/4-Wire

On

(4-Wire) FDX

S2-7

2-Wire/4-Wire

Off

(4-Wire) FDX

 

 

 

 

 

S2-8

V.54

Off

V.54 Enabled

 

 

 

 

 

Switches S2-1 and S2-2: Word Length

Switches S2-1 and S2-2 are set in combination to determine the word length for asynchronous data, including the start and stop bits.

S2-1

S2-2

Setting

Off

On

8 bits

On

On

9 bits

Off

Off

10 bits

On

Off

11 bits

Switch S2-3: Extended Signaling Rate

The setting for switch S2-3 determines the range of variability the Model 1065 Series “looks for” in asynchronous data rates (i.e., the actual variance from a given frequency level the Model 1065 Series will tolerate).

S2-3

Setting

Off

-2.5% to +1%

On

-2.5% to +2.3%

Switches S2-4 and S2-5: RTS/CTS Delay

The combined settings for switches S2-4 and S2-5 determine the amount of delay between the time the unit “sees” RTS and when it sends CTS. Options are no delay, 7 ms and 53 ms.

S2-4

S2-5

Setting

On

On

7 ms

Off

On

53 ms

On

Off

No delay

Off

Off

No delay

Switch S2-6 & S2-7: 2-Wire/4-Wire Mode Selection

The setting for switch S2-6 and S2-7 determines whether the Model 1065 Series is operating in 2-wire or 4-wire mode.

S2-6

S2-7

Setting

On

On

4-wire (half duplex)

On

Off

4-wire (full duplex)

Off

On

2-wire (half duplex)

Switch S2-8: V.54 Loopback Test Enable

This switch enables or disables V.54 looping in the Model 1065.

S2-8

Setting

Off

V.54

Normal Operation Enabled

On

V.54

Testing Disabled

7

8

Image 5
Contents User Manual Tel 301 ServiceRadio and TV Interference Description FeaturesConfiguration Switches Model 1065 S1 Summary Table Configuration Switch SET S1Model 1065 Data Rate Settings S2 Summary Table Configuration Switch SET S2S3-1, S3-2 Selection Table for Model Configuration Switch SET S3S3 Summary Table Switch S3-6 RS-232 Initiation of Remote Loopback Test Switch S3-5 RS-232 Initiation of Local Loopback TestSwitches S3-7 and S3-8 Anti-stream Control TWO-WIRE InstallationRJ-45 Signal Two-Wire Cable Connection Via RJ-45Signal PIN# Color FOUR-WIRE InstallationRS-232 Connection FOUR-WIRE, Multipoint InstallationMultipoint Twisted Pair Connection LED Status Monitors ANTI-STREAMING Error IndicatorUsing the V.52 BER Test Independently POWER-UPV.54 Test Modes Local Analog Loopback LALAppendix a Patton Electroniics Model 1065 Specifications POWER-DOWNAppendix C Patton Electronics Model Cable Recommendations Patton Model # Description