Patton electronic Model 1065 user manual Switch S3-5 RS-232 Initiation of Local Loopback Test

Page 7

Switch S3-5: RS-232 Initiation of Local Loopback Test

The setting for switch S3-5 determines whether or not the Model 1065 local analog loopback test can be initiated by raising pin 18 on the RS-232 interface.

S3-5

Setting

On

RS-232 initiation enabled

Off

RS-232 initiation disabled

Switch S3-6: RS-232 Initiation of Remote Loopback Test

The setting for switch S3-6 determines whether or not the Model 1065 remote digital loopback test can be initiated by raising pin 21 on the RS-232 interface.

S3-6

Setting

On

RS-232 initiation enabled

Off

RS-232 initiation disabled

Switches S3-7 and S3-8: Anti-stream Control

Switches S3-7 and S3-8 are set in combination to determine the time out period for the Model 1065 Series’ anti-stream control timer.

S3-7

S3-8

Setting

Off

Off

Disabled

Off

On

12.5 seconds

On

Off

50.0 seconds

On

On

12.5 seconds

4.0 INSTALLATION

The Model 1065 operates in four twisted pair topologies: 2-wire/point-to-point, 2-wire/multipoint, 4-wire/point-to-point, and

4-wire/multipoint. In each of these topologies, the twisted pair wire must be 19 - 26 AWG "dry", unconditioned metallic wire (see Appendix C for wire recommendations). Dial-up analog circuits, such as those used with a standard Hayes-type modem, are not acceptable. The twisted pair may be shielded or unshielded. Both types yield favorable results.

The Model 1065 offers an RJ-45 jack for its twisted pair line con- nection. Figure 4 (below) shows the location of these interfaces on the rear panel of the Model 1065 Series. Connect the wire to each Model 1065 Series as described in the instructions that follow the illustration. The “+” and “-” indicators are for reference only.

Figure 4. Model 1065 rear panel.

4.1 TWO-WIRE INSTALLATION

When communicating over a single twisted pair circuit, the Model 1065 operates half duplex: that is, it transmits in only one direction at a time. This method of operation is effective for both point-to-point and multipoint applications.

In single pair point-to-point applications, you will need a pair of Model 1065s for each circuit—one at each end of the single pair wire. In single-pair multipoint applications you will need three or more Model 1065 units. These can be connected using a star topology, although a daisy chain topology is usually used.

11

12

Image 7
Contents User Manual Radio and TV Interference ServiceTel 301 Configuration Switches FeaturesDescription Model 1065 Data Rate Settings Configuration Switch SET S1Model 1065 S1 Summary Table S2 Summary Table Configuration Switch SET S2S3 Summary Table Configuration Switch SET S3S3-1, S3-2 Selection Table for Model TWO-WIRE Installation Switch S3-5 RS-232 Initiation of Local Loopback TestSwitch S3-6 RS-232 Initiation of Remote Loopback Test Switches S3-7 and S3-8 Anti-stream ControlFOUR-WIRE Installation Two-Wire Cable Connection Via RJ-45RJ-45 Signal Signal PIN# ColorMultipoint Twisted Pair Connection FOUR-WIRE, Multipoint InstallationRS-232 Connection LED Status Monitors ANTI-STREAMING Error IndicatorLocal Analog Loopback LAL POWER-UPUsing the V.52 BER Test Independently V.54 Test ModesAppendix a Patton Electroniics Model 1065 Specifications POWER-DOWNAppendix C Patton Electronics Model Cable Recommendations Patton Model # Description