Table 25. Submenus under the USB Configuration (continued)

Item

Option

Description

 

 

 

Emulation Type

[Auto]

Select the type of the USB

 

Floppy

device.

 

Forced FDD

 

 

Hard Disk

 

 

CDROM

 

 

 

 

Table 26. Submenus under the Hardware Health Configuration

 

 

 

Item

Option

Description

 

 

 

Items and options with BMC configuration:

 

 

 

 

Auto Fan Control

Disabled

If this option is set to

 

[Enabled]

Disabled, the fan runs at the

 

 

full speed; if this option is

 

 

set to Enabled, the fan speed

 

 

is controlled by the system

 

 

temperature.

 

 

 

PWM Minimal Duty Cycle

[60% Duty Cycle]

Select the PWM Minimal

 

45% Duty Cycle

Duty Cycle for the fan:

 

30% Duty Cycle

60%-100%, 45%-100%, or

 

 

30%-100%.

 

 

 

Sensor Data Register

Read Only

The sensor data in this

Monitoring

 

option is for read only. The

 

 

detected data includes the

 

 

temperature, voltage and fan

 

 

speed.

 

 

 

Items and options without BMC configuration:

 

 

 

 

H/W Health Function

Disabled

Enable or disable the

 

[Enabled]

hardware monitor function.

 

 

 

Auto FAN Control

Disabled

If this option is set to

 

[Enabled]

Disabled, the fan runs at the

 

 

full speed; if this option is

 

 

set to Enabled, the fan speed

 

 

is controlled by the system

 

 

temperature.

 

 

 

PWM Minimal Duty Cycle

[60% Duty Cycle]

Select the PWM Minimal

 

45% Duty Cycle

Duty Cycle for the fan:

 

30% Duty Cycle

60%-100%, 45%-100%, or

 

 

30%-100%.

 

 

 

Fan Failure LED Indication

Disabled

Enable or disable the fan

 

[Enabled]

alarm function. If this option

 

 

is set to Enabled, a message

 

 

about fan failure will be

 

 

displayed on the POST

 

 

screen when the rotational

 

 

speed of each fan is less than

 

 

800 rpm.

 

 

 

Hardware Health Event

Read Only

The sensor data in this

Monitoring

 

option is for read only. The

 

 

detected data includes the

 

 

temperature and system fan

 

 

rotational speed.

 

 

 

Note: The settings in [ ] are the default settings in the Setup Utility program.

108ThinkServer RD230 Types 1043, 1044, 4010, and 4011: Hardware Maintenance Manual

Page 114
Image 114
Lenovo RD230 Option Description Items and options with BMC configuration, Items and options without BMC configuration

RD230 specifications

The Lenovo RD240 and RD230 are key players in the realm of enterprise-class servers, leveraging advanced technologies to deliver efficiency, reliability, and performance. These servers are designed to cater to the demands of small to medium-sized businesses, providing robust solutions for various workloads.

The Lenovo RD240 is a 2U rack server that features dual-socket support for Intel Xeon processors. This capability allows it to handle intensive computational tasks seamlessly, making it ideal for virtualized environments and database management. Equipped with up to 512GB of DDR3 memory, the RD240 ensures high memory bandwidth and reduced latency, improving overall system responsiveness.

In terms of storage, the RD240 supports a versatile range of options, with configurations allowing for up to twelve 3.5-inch hard drives or a combination of SSDs and HDDs. This flexibility enables businesses to tailor their storage solutions based on performance and capacity needs. Additionally, the server includes integrated RAID options, which enhance data protection and availability.

On the other hand, the RD230 is a compact 1U rack server that prioritizes space efficiency without compromising on performance. Like its larger counterpart, the RD230 supports dual Intel Xeon processors, but its design focuses on providing a more streamlined solution for environments with limited rack space. With support for up to 128GB of RAM, the RD230 can efficiently handle various applications, from web hosting to application serving.

Both servers are equipped with advanced management tools, such as the Lenovo XClarity Controller, which simplifies system monitoring and maintenance. This allows IT administrators to deploy updates, monitor hardware health, and manage resources with ease, leading to minimized downtime and optimized performance.

Furthermore, Lenovo places a strong emphasis on energy efficiency, ensuring that both the RD240 and RD230 have features like power management and cooling technologies. These innovations reduce their carbon footprint while lowering operating expenses, making them attractive choices for environmentally-conscious businesses.

In summary, the Lenovo RD240 and RD230 servers offer a blend of performance, flexibility, and efficient management, catering to the diverse needs of modern enterprises. With their robust features and reliable characteristics, they stand as dependable solutions for businesses looking to enhance their IT infrastructure while supporting future scalability.