Patton electronic NetLink-E1 2715 Features, General Product Description, Supported Applications

Page 4

2.0 GENERAL INFORMATION

Thank you for your purchase of this Patton Electronics product. This product has been thoroughly inspected and tested and is warrant- ed for One Year parts and labor. If any questions arise during installa- tion or use of the unit, contact Patton Electronics Technical Services at (301) 975-1007.

2.1FEATURES

Terminates E1/FE1 Circuits over a 4-Wire RJ-48C interface

Connects to standard CPE Serial Interfaces

Common Framed nx64 rates up to 1.984 Mbps

Unstructured Rate of 2.048 Mbps

G.703 or G.704 Framing (with or without CRC-4, CAS multi- frame)

Selectable AMI or HDB3 Line Coding

Configuration via Control Port or Internal DIP Switches

Seven Easy-to-Read LED Indicators Monitor Data & Diagnostics

Internal, External or Receive Recover Clocking

Also Operates as a High-Speed Point-to-Point Modem

Compact Size Plugs Directly into a Router, Switch or other DTE

Made in USA

2.2GENERAL PRODUCT DESCRIPTION

The Patton Model 2715 Network Termination Unit (NTU) terminates both 2.048 Mbps G.703 E1 (clear channel) and fractional E1 G.704 (n x 64) 4-wire circuit. housed in our MicroPak enclosure measuring only 9 x 5.3 x 2 cm (3.55 x 2.1 x 0.78 in.) the Model 2715 plugs directly into the V.35 DTE interface of a router, switvh, FRAD, multiplexer or other networking device.

The Model 2715 supports all necessary G.703/G.704 diagnostics, DTE local/remote loops, and V.54 loop up/loop down. Diagnostics are initiat- ed via the Model 2715's control port, or through the DTE or line inter- faces. Easily readable LED indicators include TD, RD, Loss of Sync (LOS), Alarm, Error, Test and Power. Configuration of the Model 2715 is done through the control port or using DIP switches.

The Model 2715 presents a RJ45 120 ohm interface to the line and a V.35 interface to the customer's device using a Male M/34 connector. An M/34 to DB-60 adapter cable is available for convenient connection to Cisco routers. The Model 2715 is powered by an external Universal Input 100-240VAC adapter.

2.3 SUPPORTED APPLICATIONS

The Model 2715 provides an E1 network termination between E1 and Fractional E1 equipment and customer premises equipment (CPE) such as a router. The Model 2715 can also be used as a high-speed short haul modem for campus applications.

2.3.1 The 2715 as the Interface between the Telco and CPE

The Model 2715 provides the interface between an E1/Fractional

E1 multiplexer and a router or switch (See below).

Model 2715

2.3.2 The 2715 as a High-Speed Short Range Modem

The Model 2715 can also be installed into high-speed campus applications. In this application, a pair of Model 2715 units operate as short range modems (See below).

Model 2715

Model 2715

5

6

Image 4
Contents User Manual Warranty Statement Patton Model Table of ContentsGeneral Information Service Information Radio and TV InterferenceCE and Telecommunication Approvals Tel 301 Email support@patton.comFeatures General Product DescriptionSupported Applications 2715 as the Interface between the Telco and CPEDIP Switch Configuration Switch SET Summary TableSwitch SW1 Line Coding Line Coding OptionsMULTIFRAMEG.704 CRC-4 MFUnframed G.703 SW3 SW4 Clock ModesSoftware Configuration Introduction to Main Menu Helpful HintsLine Format G.703 default Options G.703, G.704 System ConfigurationLine Coding HDB3 default CRC-4 Setting Disabled default Options Enabled, Disabled CAS MF Setting Disabled default Options Enabled, Disabled54 Loops Enabled default Options Enabled, Disabled Default Config Source Switch default Options EEPROM, SwitchSystem Diagnostics Local Loop Idle defaultRemote Loop Idle default Test Pattern Idle default Options Idle or SendingError Insertion Off default Options On, Off SpacebarCurrent DIP Switch Settings PasswordNI Status Unit OptionsLoop Timeout Set to Default ConfigurationService Information DTE Interface ConnectionPower Connection LED DescriptionsTXD RXDLoop V.54 & Telco Diagnostics LOSALM ERRBIT Error Rate V.52 Diagnostics Error Insertion to on511 2047Specifications Cable RecommendationsAppendix C DB9FConnector, Terminal Interface Power Supply InterfaceJumper Position for Power via DC Power Jack default Jumper Position for Power via Pin KK