Patton electronic NetLink-E1 2715 user manual Patton Model Table of Contents, General Information

Page 2

 

PATTON MODEL 2715

 

 

TABLE OF CONTENTS

 

Section

Page

1.0 General Information

2

1.1

Warranty Statement

 

1.2

Radio and TV Interference

 

1.3

CE and Telecommunication Approvals

 

1.4

Service Information

 

2.0

General Information

5

2.1Features

2.2General Product Description

2.3.1The 2715 as the Interface between the Telco and CPE

2.3.2The 2715 as a High-Speed Short Range Modem

2.3Supported Applications

3.0 Configuration

7

3.1DIP Switch Configuration

3.2Software Configuration

3.2.1Introduction to Main Menu

3.2.2System Configuration

3.2.3System Diagnostics

3.2.4Unit Options

4.0 Installation

26

4.1DTE Interface Connection

4.2Network Interface Connection

4.3Power Connection

4.3.1Using The AC Power Supply (100-240VAC)

4.3.2Supplying DC Power

4.3.3Supplying Power via pin KK

5.0 Operation

28

5.1LED Descriptions

5.2Loop (V.54 & Telco) Diagnostics

5.2.1Operating Local Loopback (LL)

5.2.2Operating Remote Digital Loopback (RDL)

5.3Bit Error Rate (V.52) Diagnostics

Appendix A - Specifications

33

Appendix B - Cable Recommendations

34

Appendix C - Factory Replacement Parts and Accessories

35

Appendix D - Interface Pin Assignments

36

Appendix E - Power Supply Interface

38

1

 

1.0 GENERAL INFORMATION

Thank you for your purchase of this Patton Electronics product. This product has been thoroughly inspected and tested and is warrant- ed for One Year parts and labor. If any questions or problems arise during installation or use of this product, please do not hesitate to con- tact Patton Electronics Technical Services at (301) 975-1007.

1.1 WARRANTY STATEMENT

Patton Electronics warrants all Model 2715 components to be free from defects, and will—at our option—repair or replace the product should it fail within one year from the first date of shipment.This warran- ty is limited to defects in workmanship or materials, and does not cover customer damage, abuse, or unauthorized modification. This product contains no serviceable parts; therefore the user shall not attempt to modify the unit in any way. If this product fails or does not perform as warranted, your sole recourse shall be repair or replacement as described above. Under no condition shall Patton Electronics be liable for any damages incurred by the use of this product. These dam- ages include, but are not limited to, the following: lost profits, lost sav- ings and incidental or consequential damages arising from the use of or inability to use this product. Patton Electronics specifically dis- claims all other warranties, expressed or implied, and the installation or use of this product shall be deemed an acceptance of these terms by the user. In the event the user detects intermittent or continuous prod- uct malfunction due to nearby high power transmitting radio frequency equipment, the user is strongly advised to use only data cables with an external outer shield bonded to a metal or metalized connector.

2

Image 2
Contents User Manual General Information Patton Model Table of ContentsWarranty Statement CE and Telecommunication Approvals Service InformationRadio and TV Interference Tel 301 Email support@patton.comSupported Applications FeaturesGeneral Product Description 2715 as the Interface between the Telco and CPESwitch SW1 Line Coding DIP Switch ConfigurationSwitch SET Summary Table Line Coding OptionsUnframed G.703 SW3 SW4 MULTIFRAMEG.704CRC-4 MF Clock ModesSoftware Configuration Introduction to Main Menu Helpful HintsLine Coding HDB3 default System ConfigurationLine Format G.703 default Options G.703, G.704 54 Loops Enabled default Options Enabled, Disabled CRC-4 Setting Disabled default Options Enabled, DisabledCAS MF Setting Disabled default Options Enabled, Disabled Default Config Source Switch default Options EEPROM, SwitchSystem Diagnostics Local Loop Idle defaultError Insertion Off default Options On, Off Remote Loop Idle defaultTest Pattern Idle default Options Idle or Sending SpacebarNI Status Current DIP Switch SettingsPassword Unit OptionsService Information Loop TimeoutSet to Default Configuration DTE Interface ConnectionTXD Power ConnectionLED Descriptions RXDALM Loop V.54 & Telco DiagnosticsLOS ERR511 BIT Error Rate V.52 DiagnosticsError Insertion to on 2047Specifications Cable RecommendationsAppendix C DB9FJumper Position for Power via DC Power Jack default Connector, Terminal InterfacePower Supply Interface Jumper Position for Power via Pin KK