Patton electronic NetLink-E1 2715 Connector, Terminal Interface, Power Supply Interface

Page 20

APPENDIX D

(continued)

PATTON MODEL 2715

INTERFACE PIN ASSIGNMENTS

M/34 Connector, Terminal Interface

Pin #

Signal

AGND (Earth Ground/Shield)

BSGND (Signal Ground)

DCTS (DCE Source)

EDSR (DCE Source, Always On)

FCD (DCE Source)

L LL (Local Loop, DTE Source)

MTM (Test Mode Indicator (DCE Source)

NRL (Remote Loop, DTE Source)

PTD (Transmit Data +, DTE Source)

R RD (Receive Data +, DCE Source)

S TD/ (Transmit Data -, DTE Source)

T RD/ (Receive Data -, DCE Source)

U SCTE (Transmit Clock+, DTE Source)

V RC (Receiver Clock +, DCE Source)

W SCTE/ (Transmit Clock-, DTE Source)

X RC/ (Receiver Clock -, DCE Source)

Y TC (Transmitter Clock +, DCE Source)

AA TC/ (Transmitter Clock -, DCE Source)

KK Aux. Power Input (+5VDC @ 300mA)

APPENDIX E

PATTON MODEL 2715

POWER SUPPLY INTERFACE

Via Main 5VDC power jack (J1)

Center Pin: +5VDC @ 300 mA

Outer Barrel: Ground

Jumper Position for Power via DC Power Jack (default):

Via Auxiliary Power Supplied to Pin KK on V.35 connector

DC Power supplied to pin KK must be 5VDC ± 5%, 300mA minimum.

Jumper Position for Power via Pin KK:

NOTE: Model 2715 is factory configured to accept power from the enclosed DC wall adapter (See Sections 4.3.1 and 4.3.2 above). If you wish to supply power via pin KK on the interface, you must change the setting of the power supply jumper on the printed circuit board. All power sources must be SELV (Circuit, Safety Extra Low Voltage) specified. (See CENELEC EN60950, Section 1.2.8.5)

37

38

Image 20
Contents User Manual General Information Patton Model Table of ContentsWarranty Statement Service Information Radio and TV InterferenceCE and Telecommunication Approvals Tel 301 Email support@patton.comFeatures General Product DescriptionSupported Applications 2715 as the Interface between the Telco and CPEDIP Switch Configuration Switch SET Summary TableSwitch SW1 Line Coding Line Coding OptionsMULTIFRAMEG.704 CRC-4 MFUnframed G.703 SW3 SW4 Clock ModesSoftware Configuration Introduction to Main Menu Helpful HintsLine Coding HDB3 default System ConfigurationLine Format G.703 default Options G.703, G.704 CRC-4 Setting Disabled default Options Enabled, Disabled CAS MF Setting Disabled default Options Enabled, Disabled54 Loops Enabled default Options Enabled, Disabled Default Config Source Switch default Options EEPROM, SwitchSystem Diagnostics Local Loop Idle defaultRemote Loop Idle default Test Pattern Idle default Options Idle or SendingError Insertion Off default Options On, Off SpacebarCurrent DIP Switch Settings PasswordNI Status Unit OptionsLoop Timeout Set to Default ConfigurationService Information DTE Interface ConnectionPower Connection LED DescriptionsTXD RXDLoop V.54 & Telco Diagnostics LOSALM ERR BIT Error Rate V.52 Diagnostics Error Insertion to on 511 2047Specifications Cable RecommendationsAppendix C DB9FConnector, Terminal Interface Power Supply InterfaceJumper Position for Power via DC Power Jack default Jumper Position for Power via Pin KK