Patton electronic 4900 user manual Login, Changing the WAN IP address

Page 40

SmartNode 4900 User Manual

4 • Getting started with the SmartNode 4900 Series

 

 

Login

To access the SmartNode, start the Telnet application. Type the default IP address for the router into the address field: 192.168.1.1. Accessing your SmartNode via a Telnet session displays the login screen. Type the factory default login: administrator and leave the password empty. Press the <Enter> key after the password prompt.

login:administrator password: <Enter> 192.168.1.1>

After you have successfully logged in you are in the operator execution mode, indicated by > as command line prompt. With the commands enable and configure you enter the configuration mode.

192.168.1.1>enable

192.168.1.1#configure

192.168.1.1(cfg)#

Changing the WAN IP address

Select the context IP mode to configure an IP interface.

192.168.1.1(cfg)#context ip router 192.168.1.1(ctx-ip)[router]#

Now you can set your IP address and network mask for the interface ETH 0/0 (WAN). Within this example a network 172.16.1.0/24 address is assumed. The IP address in this example is set to 172.16.1.99 (you should set this the IP address given to you by your network provider).

172.16.1.99(ctx-ip)[router]#interface eth0 172.16.1.99(if-ip)[eth0]#ipaddress 172.16.1.99 255.255.255.0 2002-10-29T00:09:40 : LOGINFO : Link down on interface eth0. 2002-10-29T00:09:40 : LOGINFO : Link up on interface eth0. 172.16.1.99(if-ip)[eth0]#

Note If your WAN connection's IP address is assigned via DHCP, refer to Chapter 21, "DHCP configuration" in the SmartNode Series Smart- Ware Software Configuration Guide for information on configuring DHCP. Copy this modified configuration to your new start-up con- figuration. Upon the next start-up the system will initialize itself using the modified configuration.

172.16.1.99(if-ip)[eth0]#copy running-config startup-config 172.16.1.99(if-ip)[eth0]#

The SmartNode can now be connected to your network.

1. Configure IP address

40

Image 40
Contents SmartNode Mailsupport@patton.com Summary Table of Contents Table of Contents LEDs status and monitoring Factory Configuration End User License Agreement List of Figures List of Tables Audience About this guideStructure Precautions Impaired functioningSafety when working with electricity Sonnel. Opening the SmartNode case will void the warrantyPreventing Electrostatic Discharge Damage General observationsTypographical conventions used in this document General conventionsChapter contents General informationSmartNode 4900 Series overview Model SN4932 IpChannel BankSmartNode 4900 Series detailed description Power LED SmartNode 4900 Series front panelSmartNode 4900 Series rear panels Model SN4932Reset button behavior ExpansionApplications overview Introduction Multiservice carrier access over leased linesSmartNode 4900 Series applications Enterprise FXS concentration and extension over IP and T1/E1 Bulk analog line extensionsHardware installation Planning the installation Installation checklist Site logNetwork diagram Configuration toolsAC Power Mains Network informationInstalling the IpChannel Bank IpChannel Bank chassis installationLocation and mounting requirements Unpacking the Model SN4900 series IpChannel BankConnecting the FXS ports Connecting cablesConnecting the FXO ports Connecting the Ethernet ports RJ-45 Jack Signal NameConnecting the serial port Pin DescriptionConnecting power Grounding the Model SN4900-AC and DC unitsInstalling the power cables-AC units Grounding stud and power cable retainer clipInstalling the power cables-DC units DC connector, -DC and +DC input viewHardware installation Getting started with SmartNode 4900 Series Connecting the SmartNode to your laptop PC Configure IP address Factory-default IP settingsConnect to the RS-232 console port HyperTermLogin Changing the WAN IP addressConnecting the SmartNode to the network Loading the configuration optionalBootloader Start BootloaderStart-up with factory configuration Load a new application image SmartWare via TftpCopy tftp//tftpserveraddress/server path/b1 flash Additional information Load a new application image SmartWare via the serial linkLEDs status and monitoring Status LEDs Contacting Patton for assistance Warranty coverage Contact informationOut-of-warranty service Returns for creditReturn for credit policy RMA numbersAppendix a Compliance information Compliance Radio and TV interference FCC PartCE Declaration of Conformity Authorized European RepresentativeWatchfield Swindon, Wilts SN6 8TD, UK FCC Part 68 Acta Statement FXO ports Industry Canada Notice FXO PortsAppendix B Specifications Voice connectivity FXS Voice connectivity FXOEthernet interface Console portVoice processing signaling dependent FXS portsFXO ports PPP and Frame-Relay supportIP services Voice signalingVoice routing-session router Dimensions Weight and power dissipationManagement Operating environmentPower supply Identification of the SmartNode devices via SnmpUniversal AC version DC versionAppendix C Port pin-outs Ethernet 10Base-T and 100Base-T port EIA-561 RJ-45 8-pin portSync Serial port Band marked color-codes for the 64-pin RJ-21X connector FXS and FXO portsBrown Black Violet Appendix D Factory Configuration Factory Configuration Appendix E End user license agreement End User License Agreement Termination Other licensesAppendix F Installation checklist Task Verified by Date Appendix G Accessories Description Part Number

4900 specifications

The Patton Electronic 4900 is a robust and innovative solution in the realm of telecommunications and data networking. Designed to meet the challenges of modern network demands, it combines reliability with advanced technological features that make it a preferred choice for businesses of all sizes.

One of the standout features of the Patton 4900 is its versatility in supporting various communication protocols. This unit is capable of functioning as a VoIP gateway, enabling seamless voice communication over Internet Protocol networks. Its ability to bridge different telecommunications networks simplifies integration tasks and enhances operational efficiency.

The Patton 4900 is equipped with a powerful digital signal processor (DSP) that facilitates high-quality voice and video transmission. This technology reduces latency and ensures crystal-clear communication, making it ideal for enterprises that depend on reliable voice connectivity. Additionally, the DSP allows for advanced echo cancellation and noise reduction, further enhancing voice clarity in various environmental conditions.

Security is a paramount concern in today's networking landscape, and the Patton 4900 addresses this with robust encryption capabilities. It supports various encryption protocols, ensuring that sensitive data remains protected during transmission. This makes it an excellent choice for organizations that handle confidential information.

With multiple interfaces, including analog and digital ports, the Patton 4900 offers flexibility when connecting to existing infrastructure. Organizations can easily transition from legacy systems to modern VoIP solutions without undergoing extensive overhauls of their current setup. This adaptability is crucial for businesses looking to upgrade their communication systems without disrupting ongoing operations.

Moreover, the device is designed for ease of use, featuring a user-friendly interface that simplifies configuration and management. Network administrators can quickly set up and monitor the unit, minimizing downtime and maximizing productivity.

The Patton Electronic 4900 is not only built for high performance, but it also boasts a rugged hardware design that ensures durability in various operating conditions. This reliability reduces the likelihood of equipment failure, thereby minimizing the total cost of ownership.

In summary, the Patton Electronic 4900 stands out in the telecommunications market due to its advanced features, including versatility in communication protocols, high-quality voice and video transmission, robust security measures, flexible interfaces, ease of use, and reliable hardware. These characteristics make it an exceptional choice for organizations seeking to enhance their communication capabilities while ensuring the integrity and security of their data.