Patton electronic 1053 S1-1 S1-2 Sync Data Rate Async. Data Rate, S1-3 Setting, S1-4 Setting

Page 9

Each setting represents one synchronous data rate and one asynchro- nous data rate.

S1-1

S1-2

Sync Data Rate

Async. Data Rate

 

 

 

 

On

On

128 kbps

115.2 kbps

Off

On

64 kbps

57.6 kbps

 

 

 

 

On

Off

56 kbps

76.8 kbps

 

 

 

 

Off

Off

32 kbps

0–38.4 kbps

 

 

 

 

Note If the S2-1 switch is positioned in the OFF position, the 128 kbps sync data rate/0–38.4 kbps async data rate option is selected.

Switch S1-3:Must be set to the ON position (Reserved).

S1-3

On

Setting

Reserved

Switch S1-4:Must be set to the ON position (Reserved).

S1-4

Setting

 

 

On

Reserved

Switch S1-5: Asynchronous/Sync Operation. Use Switch S1-5 to configure the Model 1053 for async/sync operation. For synchronous data rates set switch S1-5 OFF. For asynchronous rates set switch S1-5 ON.

S1-5

Setting

 

 

Off

Sync

On

Async

 

 

Switches S1-6 and S1-7: System Clock Mode. Use Switches S1-6 and S1-7 to configure the 1053 for internal, or receive recover clock mode.

S1-6

S1-7

Clock Mode

Description

 

 

 

 

On

On

Internal

System clock generated internally

Off

On

External (DTE)

System clock derived from termi-

 

 

 

nal interface

 

 

 

 

On

Off

Receive Recover

System clock derived from the

 

 

 

received line signal

 

 

 

 

Off

Off

Hardware Reset

 

 

 

 

 

9

Image 9
Contents User Manual Table of Contents Page Warranty Information FCC InformationCE Notice Tel 301 Mailsupport@patton.com ServiceFeatures General InformationDescription Configuring the Hardware DIP Switches ConfigurationOpening the Model 1053 case Configuring DIP Switch S1S1-3 Setting S1-4 SettingS1-1 S1-2 Sync Data Rate Async. Data Rate Other Model 1053 for receive recover clock mode Configuring DIP switch S2S1-8 Connecting the Twisted Pair Interface InstallationConnecting the Model 1053/A RS-232 Connecting the Model 1053/A RS-232 to a DTE DevicePower Connection DC Power Universal AC Power 100-240 VACPort at +1 301 975-1007, via our web site at For more informationOperation POWER-UPLED Status Monitors LEDLED Status Indicators Control SignalsConnectors PowerWeight Temperature RangeAltitude HumidityModel # Description Appendix BPin # Signal DB-25 Female ConnectorAppendix C RS-232 InterfacePage Copyright Patton Electronics Company All Rights Reserved