Polycom DOC2559B manual RMX 4000 System Capacities, Conferencing Capacities, Environment

Page 9

Polycom RMX 4000 Hardware Guide

Table 1-1Polycom RMX 4000 Specifications (Continued)

Environment

Operating temperature

10°– 40°C (50°– 104°F).

 

 

Storage temperature

-40°– 70°C (40°– 158°F).

 

 

Relative humidity

15% - 90% no condensing.

 

 

Operating altitude

60m below sea level, up to 3,000 m (10,000 ft.).

 

 

Operating ESD

4kV.

 

 

RMX 4000 System Capacities

Conferencing Capacities

The following table summarizes the different system capacities.

Table 1-2System Functions and Capacities RMX 4000

System Functions

MPM+ Mode

MPMx Mode

 

 

 

Maximum number of Video participants in a

160

180

conference

 

 

 

 

 

Maximum number of PSTN participants in a

400

400

conference

 

 

 

 

 

Maximum number of VOIP participants in a

800

720

conference

 

 

 

 

 

Maximum number of Audio calls per second

5

5

 

 

 

Maximum number of Video calls per second

2

2

 

 

 

Maximum number of Conferences

800

800

 

 

 

Maximum number of Meeting Rooms

2000

2000

 

 

 

Maximum number of Entry Queues

80

80

 

 

 

Maximum number of Profiles

80

80

 

 

 

Maximum number of Conference Templates

200

200

 

 

 

Maximum number of SIP Factories

80

80

 

 

 

1-3

Image 9
Contents Polycom RMX 4000 Hardware Guide USA Συμμορφωνεται Προσ ΤΙΣ Ουσιωδεισ Απαιτησεισ ΚΑΙ ΤΙΣ Russian Communication Certificate Regulatory NoticesTable of Contents Component Replacement Hardware Description Power Consumption Power SupplyPhysical Media ProtocolsRMX 4000 System Capacities Conferencing CapacitiesEnvironment System Functions MPM+ Mode MPMx Mode Resource Capacities per Card Assembly MPMx CardMPM+ Card MPM+ Resource Capacities per Card Type MPM, MPM+ and MPMxMCU Card Configuration Mode Guidelines Card Configuration Mode Selection During Startup / RestartMPMx and MPM+ Modes Site Safety Requirements Safety RequirementsRack Mount Safety Precautions General Installation PrecautionsUnpacking the RMX Installing the RMXPolycom RMX 4000 Hardware Guide Installing the RMX in a Rack or as a Standalone Standalone RMX 4000 InstallationRack Mount Preparations Placing the RMX 4000 in a 19 Rack 2Installing chassis runners and RMX in a rack3RMX 4000 Rack Mount 4Removing and attaching 19 and 23 brackets Placing the RMX 4000 in a 23 RackTo reverse mount the RMX 4000 on a 19 rack Reverse Mounting the RMX 4000 in a RackConnecting the RMX 4000 to Power Sources Connecting the RMX 4000 to AC Power Connecting the RMX 4000 to -48DC Selv Power Type a Type B Types of DC Circuit Breakers installed on the RMXTo connect the cables AC and DC systems RTM-IP Connecting Cables on the RMXFirst-time Power-up RMX 4000 Front Panel RMX 4000 ComponentsShows the front panel of an RMX 4000 DC system Component Description Component Description 9RMX 4000 AC Rear View RMX 4000 Rear Panel10RMX 4000 DC Rear View RTM-IPFollowing items appear on the RMX 4000 rear panel Standby button Toggle between CPU activation and standby RTM IsdnISDN/PSTN Clock Source RTM LANDC Power Rail Module AC Power Entry Module PEMComponent Slot Allocation Slot ID/No Card/Component RequirementRTM ISDN/RTM RMX 4000 Front Panel LEDs ComponentLED Color Description Card Insertion Initiated If during Card removal Initiated The cardCntl 4000 Unit RMX 4000 Rear Panel LEDs RTM-IPLED Color Description Name Function Name RTM LANRTM Isdn Hardware Description Component Replacement Component Replacement Handle Using the Modified PMC Compatible Ejector LeverReplacing the Cntl 4000 Module Replacing an AC Power Supply Module Replacing an AC Power Entry Module PEM Replacing a DC Power Rail Module PRM Component Replacement Carefully slide the Fan drawer out through the front panel Replacing the Fan DrawerInserting an Air Filter Optional in the Fan Drawer Removing the MPM+/MPMx Card from the MCU Replacing an Faulty MPM+/MPMx CardComponent Replacement Installing the Replacement MPM+/MPMx Card Replacing the RTM Isdn Card Installing an MPM+/MPMx Card on the RMXPRI Cables Replacing the RTM-IP Replacing the RTM LAN Replacing the Fabric Switch Module FSM Polycom RMX 4000 Hardware Guide