Polycom MGC-100, MGC-50 Regulatory Notices, United States Federal Communication Commission FCC

Page 3

Regulatory Notices

United States Federal Communication

Commission (FCC)

Part 15: Class A Statement. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. Test limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio-frequency energy and, if not installed and used in accordance with the instruction manuals, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his or her own expense.

Part 68: Network Registration Number. This equipment is registered with the FCC in accordance with Part 68 of the FCC Rules. This equipment is identified by the FCC registration number.

If requested, the FCC registration Number and REN must be provided to the telephone company.

Any repairs to this equipment must be carried out by Polycom Inc., or our designated agent. This stipulation is required by the FCC and applies during and after the warranty period.

United States Safety Construction Details

Unit is intended for RESTRICTED ACCESS LOCATION.

Unit is to be installed in accordance with the National Electrical Code.

The branch circuit overcurrent protection shall be rated 20 A for the AC system.

This equipment has a maximum operating ambient of 40°C, the ambient temperature in the rack shall not exceed this temperature.

For DC system only:

Use 10 AWG copper conductors.

Connect to a reliably grounded 48 V DC SELV source.

Caution: This equipment has a connection between the grounded conductor of the DC supply circuit and the grounding conductor. See Installation Instructions.

This equipment shall be located in the same immediate area (such as, adjacent cabinets or any other equipment that has a connection between the grounded conductor of the same DC supply circuit and the grounding conductor, and also the grounding connection of the DC system.) The DC system shall not be grounded elsewhere.

Canadian Department of Communications

This Class [A] digital apparatus complies with Canadian ICES-003.

Notice: The Industry Canada label identifies certified equipment. This certification means that the equipment meets telecommunication network protective, operational and safety requirements as prescribed in the appropriate Terminal Equipment Technical Requirements document(s). The Department does not guarantee the equipment will operate to the user's satisfaction.

Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment must also be installed using an acceptable method of connection. The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations. Repairs to certified equipment malfunctions, may give the telecommunications company causes to request the user to disconnect the equipment.

Users should ensure for their own protection that the

electrical ground connections of the power utility, telephone lines and internal metallic water pipe system, if present, are connected together. This precaution may be particularly important in rural areas.

Caution: Users should not attempt to make such connections themselves, but should contact the appropriate electric inspection authority, or electrician, as appropriate.

Image 3
Contents Version MGC-50/MGC-100Catalog No. DOC2102C Version United States Federal Communication Commission FCC Regulatory NoticesEC Mark R&TTE Directive Table of Contents Basic Operations Management Tools MGC-50/MGC-100 Getting Started Guide System Overview Before You BeginMGC Unit Main Features MGC-50/MGC-100 Specifications Physical MGC-50 MGC-100Protocols MGC-50/MGC-100 External MGC-50/MGC-100 Communications Network Interfaces MGC-50/MGC-100IP H.323 and SIP SerialPower Supply MGC-50 MGC-100 Conference Setup MGC-50/MGC-100Diagnostics MGC-50/MGC-100 Serviceability MGC-50/MGC-100 ReliabilityNetwork Equipment, Numbers and Addresses Hardware Description MGC-100 Front Panel MGC-100 Components LocationMGC-100 Rear Panel with External Connectors MGC-100 Nebs Standard Front Panel MGC-100 Nebs Standard Rear Panel with External Connectors MGC-50 Front Panel MGC-50 Components LocationMGC-50 Rear Panel with External Connector MGC Unit Components DescriptionComponent Description Component MGCHardware Description Initial IP Configuration Initial System ConfigurationMGC-50 Rear Panel Attaching the Monitor and Key Board to the MGC-50 Type C\\mcu\cfgedit lan.cfg and press EnterTo install the MGC Manager software Installing the MGC ManagerInitial System Configuration To start the MGC Manager application Starting the MGC ManagerTo define an MCU Connection Defining an MCUTo connect the operator workstation to an MCU Connecting to an MCUIP Network Service Configuring the Network ServicesDefining an Isdn Network Service Isdn Network ServiceExpand the Network Services tree Field Description Settings dialog box, define the following parametersPRI Settings dialog box, define the following parameters Sub Service Dialog Box Options Click Next to continue Spans and Phones dialog box opens Define the Spans and Phones parameters as follows Add Span dialog box opens Define the following parameters To delete a circuit identification entry To delete a dial-in number entry Card Settings Common Parameters dialog box opens Card Settings NET-8 Network Parameters dialog box opensClick the Net-8 Network Parameters tab Initial System Configuration Option Description IP Network Services To define an IP Network ServiceService Settings Options Static Routes Field Description NetworkDefining Static Routes Field Description Quality Of ServiceField Defining Quality of ServiceClick the Quality of Service button QoS of Ethernet Service dialog box opensTOS Initial System Configuration DNS Name DNS Server AddressesH.323 dialog box opens Field Description Gatekeeper Service Mode Board Hunting In this mode, the MCU is Cont PseudoGatekeeper-AVF Applicable to Click Next Gatekeeper Modes Basic Board PseudoTypes Hunting Gatekeeper Gateway Get SIP Servers Automatically Field Description ServersRegistrations Registration ModeSIP Proxy Registration Mode Comment Field Description Transport Field Description SIP Servers Field Description Outbound Proxy MGC-50/MGC-100 Getting Started Guide IP Span dialog box opens 323 DhcpField Field Description Enable Fixed Ports Port RangeDefinitions Definitions Field Description Port RangeNAT Traversal Field Description When fixed portsAre exhausted Allocation ports dynamically to allocate anyIcon Description Assigning Network Services to the IP/IP+ Cards To assign IP service settings to the IP cardExpand the MCU Configuration tree Click the IP-Network Parameters tab MGC-50/MGC-100 Getting Started Guide On-Demand Reservation-less Conferencing About ConferencesMeeting Rooms Scheduled ConferencesVideo Conference Attributes Entry Queue Reservation Templates Default Reservation TemplatesReservations Database window opens Starting a ConferenceBasic Operations Viewing the Conference Dial-in Properties Participants Connecting to a Conference/Entry QueueDialing-in to a Conference/Entry Queue ISDN/PSTN ParticipantsSIP participants General Monitoring Monitoring On Going ConferencesExpand the On Going Conferences tree Filtering Option Description Participant Monitoring Filter dialog box opensExpand the On Going Conferences or Reservations tree To view the list of participants in the Browser paneTo list the participants in the Status pane To check the properties of a participant Participant Level MonitoringAdding a Participant to a Conference Operations Performed During On Going ConferencesProperties Identification dialog box opens To add a new participant to a ConferenceBasic Operations Conference Properties dialog box opens To add a pre-defined participant to a conferenceBasic Operations To manually establish a Dial-out connection Making Dial-Out ConnectionsTo disconnect a participant Disconnecting ParticipantsTo delete a participant Muting a ParticipantTo mute a participant using MGC Manager Manager User’s Guide, Volume I, ChapterLocking and Unlocking a Conference To Lock or Unlock a conference Changing the Conference DurationTo change the duration of an On Going Conference To terminate a conference manually Terminating a Conference ManuallyConference Properties Video Sources dialog box opens Changing the Layout in a Continuous Presence ConferenceMGC-50/MGC-100 Getting Started Guide To define a new Audio Only Entry Queue Defining a New Audio Only Entry QueueEntry Queue Properties dialog box opens Defining a New Audio Conference MGC-50/MGC-100 Getting Started Guide Defining an On Going Audio Conference To define a new On Going Audio ConferenceConference Properties General dialog box opens MGC-50/MGC-100 Getting Started Guide Properties Settings dialog box opens MGC-50/MGC-100 Getting Started Guide Defining a New Audio Only Meeting Room To define a New Meeting RoomConference Properties Participants tab is displayed Properties Meet Me Per Conf dialog box opens Click the Meet Me Per Conf tabDefining a New Audio Conference MGC-50/MGC-100 Getting Started Guide Defining a New Video Entry Queue Defining a New Video ConferenceTo define a new Video Entry Queue Target Conferences area Setting an Entry Queue as Default To set an Entry Queue as defaultSIP Factories list To create a target conference from an Entry Queue Creating a Target Conference from an Entry QueueTo create an On Going Conference Creating an On Going Video ConferenceDefining a New Video Conference Properties Settings dialog box opens Conference On Port Line Rate Minimum Thresholds MGC-50/MGC-100 Getting Started Guide Defining a New Video Conference To define a New Video Meeting Room Defining a New Video Meeting RoomTo view the MCU resources Resource ReportColumn Title Description Resources Report Network Resources Resource Report Network Resources Details Resources Report Media Resources Port-Unit Allocation Area Management Tools To list an MCU’s functional modules Listing the Installed CardsMCUs Cards Status Columns Administrator’s Guide, Chapter To view the Faults list MCU Faults ReportFaults Columns Field Description Reset MCU To reset the MCUObtaining Additional Information
Related manuals
Manual 8 pages 58.71 Kb

MGC-50, MGC-100 specifications

The Polycom MGC (Multipoint Gateway Controller) series includes notable models such as MGC-100 and MGC-50, designed to enhance video and audio conferencing capabilities in various organizational setups. These systems are pivotal for facilitating effective communication in a world where remote collaboration is increasingly essential.

The Polycom MGC-100 serves as a powerful multipoint control unit (MCU), allowing multiple concurrent video and audio sessions. It is particularly suitable for larger enterprises and organizations that require sophisticated conferencing capabilities. Supporting both standard definition (SD) and high definition (HD) video, the MGC-100 can manage high-quality video streams seamlessly. Its ability to integrate with different conferencing systems and technologies makes it a versatile tool for enterprises looking to enhance their collaboration efforts.

Some standout features of the MGC-100 include its support for a wide range of protocols, including H.323 and SIP, ensuring compatibility with various endpoint devices. This model can accommodate a substantial number of participants, depending on the configuration, with options for scalability. The system also boasts advanced features such as content sharing, enabling users to present slides, documents, and other materials during conferences.

On the other hand, the Polycom MGC-50 is designed for smaller organizations or departmental use. While it provides fewer simultaneous sessions than the MGC-100, it still offers robust features that make it ideal for moderate conferencing needs. The MGC-50 also supports both H.323 and SIP protocols, ensuring smooth interoperability with various video conferencing endpoints. This model features straightforward management capabilities, allowing administrators to set up and control conferences with ease.

Both models are built with advanced video processing technologies, ensuring high-quality audio and video transmission. The inclusion of error correction and packet loss recovery technologies further enhances user experience, minimizing disruptions during calls. The systems also support a variety of codecs, ensuring optimal performance across different network conditions.

In terms of characteristics, both the MGC-100 and MGC-50 emphasize reliability and ease of use. They come with user-friendly interfaces and remote management capabilities, making it simple for IT professionals to maintain and configure the systems. In conclusion, the Polycom MGC series, with its MGC-100 and MGC-50 models, exemplifies a commitment to quality and performance in multipoint conferencing, catering to diverse organizational needs while facilitating effective communication strategies.