Always use all four inserts of a given group as a set; NEVER use just one insert to fly a cabinet! The four insert groupings are a top group of four and a bottom group of four, some models have a group of four on the rear plane of the cabinet.
Maximum enclosure angle from vertical hang: 30˚
Always use a suitable safety chain or wire rope, looped through the top handle, and firmly attached to a suitable structural member as indicated by a certified structural engineer.
The recommended range of torque for the mounting bolt is 3 to 3 1/2 foot/lbs of torque. DO NOT OVERTIGHTEN! If an insert spins, it has been damaged, and the cabinet can not be flown!
Never transport the cabinet while mounted on an array bracket, or other mounting bracket.This may unduly stress the mounting inserts.
WARNING! (note to structural engineer)
For the Impulse® 100P the thread insertion depth of the end of the mounting bolt should not be more than 5/16" past the surface of the cabinet.
If these thread insertion depths are exceeded, then the inserts may be damaged or unseated from the cabinet, severely compromising the mounting integrity of the cabinet!
The correct mounting bolt diameter and threads per inch are: 1/4" x 20. Use of a grade five bolt is recommended.
GETTING AC POWER TO THE IMPULSE 100P
The Impulse 100P comes with an 8 foot IEC connection AC power cord. It is likely that some sort of extension cord will be used with this powered speaker system, so make sure that the extension cord is no longer than necessary, and is of a sufficient current capacity to maintain safety. Extension cords no longer than necessary and of the largest current capacity available will maximize the power output capability of the Impulse 100P’s internal amplifiers. For best results, do not power anything else from the extension cord used to power the Impulse 100P, in order to minimize the voltage drop that all extension cords cause. Running just one extension cord back to the wall plug for the entire sound system is not the way to maximize sound system performance.
The third wire ground plug on the AC plug should NEVER be removed or broken off; this seriously compromises safety.
USE OF IMPULSE 100P WITH A SUBWOOFER
The
The pole used is 36 3/16" long, and has a nominal diameter of 1 3/8".
GETTING A SIGNAL TO THE IMPULSE 100P
The Impulse 100P has a variety of ways to input a signal to the system.
The balanced line level input(s) allow the use of a 1/4" phone plug, either a standard
While the standard
7