2.2 Mounting a module – desk or rack

The Extender C5 modules can be situated on a desk (or floor) or alternatively, for larger installations, mounted within optional rack mount chassis units.

General remark

ƒFor correct operation, the local and remote units must have ground connections: At the computer end, ensure that the computer or KVM switch that the LOCAL module is connected to has a ground connection. At the keyboard/monitor/mouse end, ensure that the REMOTE module’s power supply is connected to a grounded power outlet. Alternatively, a ground connection will be made via the monitor, if the monitor is itself grounded.

ƒTry to avoid running the interconnect cable alongside power cables where possible.

Desk mount

Apply the supplied self-adhesive rubber feet to the underside of the module(s)

Rack mount

Note: The module switches are not accessible once it is inserted into the rack, therefore, check all settings before insertion.

1Place the rack securing plate (available as a separate kit) onto the front of the module and secure it with the two countersunk screws.

2Orientate the module on its side so that its labelled face is the correct way up and the securing plate is facing away from the rack.

3Slide the module into the required rack position. The rectangular cut-out in the front upper lip of the rack allows the two screws on the module’s upper edge to slide through.

4The rack mount chassis has a series of holes in its floor that are spaced to accommodate the two screws on the module’s lower edge. Ensure that the screws correctly locate into the two holes of the chosen slot. The rack securing plate on the module should now be flush with the front of the rack mount chassis.

5Use the third (pan-head) screw, in the top hole of the rack securing plate to fasten the module to the rack.

LINDY KVM Extender C5 PRO-300 Installation and Use

page 10

Image 10
Contents KVM Extender C5 PRO-300 About this manual Safety InformationWarranty information TrademarksContents Special Configuration Introduction Supplied items Installation Software can be changed. See . Flash upgrade procedure Configuration switch settingsLocal Switch Password overrideRemote Switch Remote Switches 2Desk mount Mounting a module desk or rackGeneral remark Rack mountConnections KVM+A multi-cable connectionSerial cable connection Optional power connectionTwisted pair connection Twisted pair, power and serial connections Keyboard, video and mouse connectionsAudio connections General Use Power and activity indicatorsOperation Locking and unlocking the systemSpecial configuration Password setting To exit from the configuration modeTo set a password Hot plugging and mouse restoration To override the Remote passwordWhich restore setting do I use? Recognising an IntelliMouse style mouseTo change mouse signalling protocols To restore mouse operation when hot pluggingMicrosoft and Logitech specific mouse settings Recognising an IntelliMouse driverTo use the image controls Video compensation, Image controls sharpness and brightnessTo display a suitable high contrast image SharpnessSkew Compensation Adjustment To use skew adjustmentMiscellaneous settings Report Extender C5 firmware version F 1 ReturnGet the upgrade files from Lindy Technical Support Flash upgrade procedureCreate a startup disk Reconfigure the Remote connections and begin Reconfigure the Local connections and beginCopy the downloaded files to the disk Return all connections to their usual states No video image is received at the Remote module TroubleshootingOn-screen mouse pointer does not respond to mouse movements Sound from the microphone cannot be heard or is very quiet Extender C5 AccessoriesLindy C5 Series Power distribution module Part No Lindy C5 Series Rack mount chassis Part NoFCC Compliance Statement United States European EMC directive 89/336/EECCanadian Department of Communications RFI statement