Connecting the VS-66FW

5.3 Controlling via RS-485

You can control a VS-66FWunit via any RS-485 remote controller or a PC (equipped with an RS-485 interface).

To connect an RS-485 remote controller to a VS-66FW:

1.Connect the RS-485 port on the RS-485 remote controller to the RS-485 ports on the VS-66FWunit, as follows:

￿￿Connect the “A” (+) PIN on the RS-485 remote controller to the “+” (A) PIN on the RS-485 port of the VS-66FWunit

￿￿Connect the “B” (-) PIN on the RS-485 remote controller to the “B” (-) PIN on the RS-485 port of the VS-66FWunit

￿￿If shielded twisted pair cable is used, the shield may be connected to the “G” (Ground) PIN on one of the units (for example, on the RS-485 remote controller)

2.Set the SETUP dipswitches on the VS-66FWunit as follows:

￿￿Set the first VS-66FWunit to MACHINE # 11

￿￿Set the second VS-66FWunit to MACHINE # 21 and set DIP 8 to ON, terminating the RS-485 line2

5.4Setting the Dipswitches

Figure 6 illustrates the factory default dipswitches:

 

 

Figure 6: Dipswitch Settings

 

 

Table 3: Dipswitch Settings

 

 

 

Function

DIPS

Description

Machine #

1, 2, 3, 4

Determines the position of a unit in the sequence (see section 5￿ .4.1)

Reserved

5

OFF

Reserved

6

OFF

Reserved

7

OFF

RS-485 Termination

8

ON for RS-485 Line Termination with 120￿;

 

 

OFF for no RS-485 Line Termination

1 See Table 3

2 The RS-485 line must also be terminated at the remote controller. Refer to the remote controller’s user manual for details of how to terminate the RS-485 line on the remote controller

10

KRAMER: SIMPLE CREATIVE TECHNOLOGY

Image 14
Contents Model Contents Figures TablesAddendum VS-66FW Overview IntroductionGetting Started Understanding FireWire FireWire ComplianceYour VS-66FW 6 Port FireWire Switcher Configuring as a FireWire Hub Defining the VS-66FW 6 Port FireWire Switcher Configuring the VS-66FW as a 6 Port FireWire HubVS-66FW 6 Port FireWire Switcher Front Panel VS-66FW 6 Port FireWire Switcher Features Connecting the VS-66FW Connecting the VS-66FW Rear PanelControlling via RS-232 for example, using a PC Connecting the VS-66FW 6 Port FireWire SwitcherSetting the Dipswitches Controlling via RS-485Connecting the Remote Connector Remote ConnectorDisplaying Unit Characteristics Operating the VS-66FWSwitching LEAF- Branch Combinations Confirming SettingsStoring/Recalling Input/Output Configurations LEAF-BRANCHLocking the Front Panel Downloading from the Internet Flash Memory UpgradeConnecting the PC to the RS-232 Port Upgrading FirmwareOpen Configuration File window appears Open Configuration File Select Window RS-232 Window Turn the Power switch on the VS-66FW OFF Technical Specifications Table of Hex Codes for Serial CommunicationKramer Protocol Protocol DefinitionsInstruction Codes for Protocol 2000 Relevant to the VS-66FW VIS setting = 1, which is defined as VIS from input #1 Then send HEX codes Only the first purchase customer may enforce this warranty 2900-000066 REV