Kramer Electronics VP-722DS Technical Data, 11.1 HD15 Connector Information, Fuse Replacement

Page 10

 

 

 

SE6

Sharpness

MI!

[-] minus

 

MI0

If excess minimum value

PL!

[+] plus

 

PL0

If excess maximum value

 

 

 

AU?

Return all video scaler status

 

 

 

OU?

 

AL!

ALL

 

SE?

________________________

 

 

 

IN?

 

 

 

LO1

if INPUT system locked

 

 

 

 

under AUTO mode

RE!

RESET

 

none

 

none

 

 

RE1

video scaler reset

none

 

 

LO0

INPUT system unlocked

 

 

 

 

under AUTO mode

none

 

 

LO1

INPUT system locked under

 

 

 

 

AUTO mode or change to

 

 

 

 

non-AUTO mode

11TECHNICAL DATA

11.1HD15 Connector Information

Pin

Use

1

Red 0.7v max. / 75 Ohms

2

Green 0.7v max. / 75 Ohms

3

Blue 0.7v max. / 75 Ohms

4

ID 2, passed to PC monitor pin 4

5

Ground

6

Red ground

7

Green ground

8

Blue ground

Pin

Use

9

Passed to PC monitor pin 9

10

Ground

11

Ground

12

ID 1, passed to PC monitor pin 12

13

Horizontal Sync TTL

14

Vertical Sync TTL

15

Passed to PC monitor pin 15

11.2 Fuse Replacement

The Video Scaler’s AC fuse is located next to the On/Off Switch on the rear panel and is easily accessible. If fuse replacement is necessary, be sure to use the same type and size as the original.

Kramer Electronics Ltd.

10

Image 10
Contents Video Scalers Table Of Contents Word about Video Scalers IntroductionFactors Affecting Quality of Results Specifications Video AdjustmentsConnecting the Hardware Unpacking and ContentsHOW do I GET STARTED? Connecting the Serial Cable Connecting the Video InputsConnecting the Video Output Connecting the AC PowerAuto Button About the Video ScalerInput Selecton Input ButtonOutput Button Video Signal AdjustmentOutput Selection Select, + and Buttons10 RS-232 Control of the VP-722DS Video Scaler GND DSR RTS CTS11.1 HD15 Connector Information Technical DataFuse Replacement Troubleshooting What is Covered and What is not Covered Limited WarrantyHOW Long is the Warranty HOW YOU can GET Warranty ServiceEN-50081 Exclusion of DamagesCompliance Notice CFR-47