IOGear G-CS14, G-CS12 Appendix B, Troubleshooting, Problem, Possible Cause, Action, The mouse is

Page 15
Appendix B

ä

Appendix B

Troubleshooting:

Note: If you are experiencing any erratic behavior from your MiniViewTM, first make sure there are no problems with the cables and that they are all properly connecetd.

Problem
Possible Cause
Action

 

The keyboard needs to

Disconnect the keyboard from the

 

MiniViewTM, wait a few seconds and plug it

 

be reset.

back in.

 

 

 

 

 

The keyboard is

 

Shut down the computers and disconnect the

The MiniViewTM

keyboard from the MiniViewTM. Power off

not responding.

needs to be reset.

the MiniViewTM, wait a few seconds,

 

 

reconnect the keyboard and power

 

 

 

 

MiniViewTM is in Auto

Press the [spacebar] key to exit Auto Scan or

 

Scan or Next/Last

Next/Last Mode.

 

Mode

 

 

 

 

 

The mouse needs to

Disconnect the mouse from the MiniViewTM

 

then reconnect it.

 

be reset.

 

 

 

 

 

 

The MiniViewTM

Shut down the computers and the

 

needs to be reset.

MiniViewTM. Wait a few seconds then

 

power everything on.

 

 

 

 

The MiniViewTM does not support some

 

 

combo mice (with extra buttons and wheels),

 

 

which can be used as either a PS/2 or serial

The mouse is

The mouse is in an

mouse. If the mouse is in serial mode,

unsupported mode.

switch the mouse to PS/2 mode if you wish

not responding.

 

to use the extra buttons or wheel. If the

 

 

problem persists, try using a different mouse

 

 

or a different mouse driver.

 

 

 

 

 

The MiniViewTM G-CS12 and G-CS14 were

 

 

designed to operate only with PS/2 mice and

 

A serial mouse or

PS/2 computers. PS/2-to-serial adapters will

 

serial mouse port is

not afford proper functionality when used

 

included in the

with the MiniViewTM. Please make sure all

 

system configuration

computers and mice connected in your

 

 

configuration are using 6-pin mini-Din

 

 

(PS/2) connectors.

Video is

 

We strongly recommend that you use high-

Cable quality is not

quality KVM cables, such as the ones

distorted or

included in your IOGEAR MiniViewTM

non-existant.

adequate.

package. Using inadequate cables can result

 

 

 

in video distortion.

 

 

 

Appendix B

11

Image 15
Contents Page IOGEAR is a registered trademark of ATEN Technology, Inc 1999 ATEN Technology, Inc. All Rights ReservedIBM is a registered trademark of International Business Machines, Inc ATEN is a registered trademark of ATEN Technology, IncPacking List Packing ListInstallation …………………..………… ContentsContents Features ………………………………Introduction IntroductionUses standard connectors to connect PC’s FeaturesFeatures Hot pluggable - add or remove connected PCs without poweringCables Hardware RequirementsHardware Require ConsoleInstallation InstallationInstallation Installation Operation OperationManual Port Selection 2-Port MiniViewTM Hot Key Port SelectionAuto Scan Mode Last/Next Mode Selecting the Active Port3 Press Enter Auto Scan ModeNext/Last Mode LED Display Appendix AAppendix A SpecificationsProblem Appendix BAppendix B Troubleshootinginfo@iogear.com Appendix CAppendix C Contacting IOGEARRadio & TV Interference Statement DAppendixAppendix D Limited Warrantyinfo@iogear.com IOGEAR 16560 Aston Street Irvine, CA Phone 949 Toll Free 888 Fax 949