Sanyo ABC-VW24A Troubleshooting, Specifications, Power supply, 120 V / 60 Hz, Current supply

Models: ABC-VW24A

1 32
Download 32 pages 62.51 Kb
Page 15
Image 15
Troubleshooting

Troubleshooting

Warning

¡If the device is still operating abnormally after inspecting the following, stop using the device to prevent accidents, unplug the power plug from the wall outlet and consult the place of purchase.

¡Do not attempt to repair at home as this may be dangerous.

Condition

Inspect

 

 

Repair

 

 

 

Does not operate.

¡Is the power plug securely in the wall outlet?

¡Place the power plug securely in the wall outlet.

 

 

 

Smoke and odors

¡Are the filter and pre-filter installed?

¡Install the filter and pre-filter.

are not removed.

 

 

 

 

 

¡Has the plastic protector on the filter been

¡Remove the plastic protector on the filter.

 

removed?

 

 

 

 

 

 

¡Is the filter or pre-filter dirty?

¡Replace the filter or clean the pre-filter.

 

¡Is the filter replacement lamp flashing?

 

 

 

 

 

 

¡Is the air inlet dirty and blocked?

¡Clean the air inlet.

 

 

 

The clean

¡Is the air very dirty?

¡Ventilate the room.

indicator is

¡Are any insecticides or cosmetic devices that

 

 

continuously red.

may trigger the sensor being used?

 

 

 

 

 

 

 

 

 

¡Is the sensor sensitivity adjustment slide tab set

¡Set the sensor sensitivity adjustment slide tab to

 

to “HIGH”?

“Mid” or “LOW”.

 

 

 

The add water

¡Is there water in the tank?

¡Fill the tank with tap water.

lamp is on.

 

 

¡Remove the tank and replace after waiting 20

 

 

 

seconds.

 

 

 

The add water

¡It is time to replace the water.

¡Clean the electrolyzed water unit and replace

lamp is flashing.

 

 

the water in the tank.

 

¡The electrolyzed water function has not been

¡Remove the tank and replace after waiting 20

 

used for an extended period of time.

seconds.

 

 

 

 

 

Water is leaking.

¡Has the cap been placed correctly on the tank?

¡Retighten the cap correctly.

 

 

 

 

 

¡Has the electrolyzed water unit been properly

¡Install the electrolyzed water unit properly.

 

installed?

 

 

 

 

 

 

 

There is an odor

¡This is from the electrolyzed water and is not a malfunction.

of chlorine.

 

 

 

 

 

 

 

The sterile,

¡Has the electrolyzed water unit and tank been

¡Ensure that the installation is correct.

electrolytic mist

properly installed?

 

 

is not emitted.

¡Is the electrolyzed water button turned “Off”?

¡Press the electrolyzed water button to turn “On”.

 

 

¡Is the water level in the electrolyzed water unit

¡Replace the water in the electrolyzed water unit.

 

high?

 

 

 

 

 

 

 

The Electrolyzed

¡The Electrolyzed Water lamp flashes when cleaning the water to maintain its sterilizing

Water lamp is

effect. The Water Cleaning function operates once every 8 hours for about 4 minutes.

flashing.

 

 

 

Does not operate

¡The automatic operation lamp (green) is flashing.

¡The sensor is configuring the air cleanliness

even when the air

 

 

standard. This is not a malfunction.

is dirty.

¡Is the sensor sensitivity adjustment slide tab set

¡Set the sensor sensitivity adjustment slide tab to

 

 

to “Mid” or “LOW”?

“Mid” or “HIGH”.

 

¡Is the air inlet dirty and blocked?

¡Clean the air inlet.

 

 

 

 

 

Specifications

Power supply

: 120 V / 60 Hz

Current supply

: 1.2 A

Net weight

: 15.9 lbs (7.2 kg)

English

E-14

Page 15
Image 15
Sanyo ABC-VW24A Troubleshooting, Specifications, Power supply, 120 V / 60 Hz, Current supply, 1.2 A, Net weight, English