Kramer Electronics VS-84H user manual Default Communication Parameters

Page 22

Default Communication Parameters

11 Default Communication Parameters

Table 4: Default Communication Parameters

EDID

EDID data is passed between Output 1 and Input 1

RS-232

Protocol 2000

Baud Rate:

9600

Data Bits:

8

Stop Bits:

1

Parity:

None

Command Format:

HEX

Example (Output 1 to Input 1):

0x01, 0x81, 0x81, 0x81

Ethernet

 

Default Settings

 

 

 

IP Address:

192.168.1.39

Subnet Mask:

255.255.255.0

Default Gateway:

192.168.1.1

TCP Port:

5000

UDP Port:

50000

19

Image 22 Contents
Model Contents FiguresTables Introduction Getting StartedKramer Simple Creative Technology Overview Defining the EdidAbout Hdmi About HdcpDefining the VS-84H 8x4 Hdmi Matrix Switcher Recommendations for Best PerformanceFeature Function ETH Reset Button Using the IR Transmitter Installing the VS-84H in a Rack Connecting the VS-84H 8x4 Hdmi Matrix Switcher Connecting the VS-84H 8x4 Hdmi Matrix SwitcherSwitching an Input to an Output Operating the VS-84H 8x4 Hdmi Matrix SwitcherAcquiring the Edid Acquiring the Edid from Several Outputs Storing and Recalling a Switching Setting from a Preset Connecting to the VS-84H 8x4 Hdmi Matrix Switcher via RS-232Select Properties Upgrading the Firmware Internet Protocol TCP/IP Properties WindowTechnical Specifications Default EdidDefault Edid Detailed timing #5 1280x720p at 50Hz Default Communication Parameters Default Communication ParametersKramer Protocol Protocol DefinitionsInstruction Codes for Protocol 82 ie. request the number of outputs Only the first purchase customer may enforce this warranty SePPKPPPcSS