Crestron electronic CP-X8150, CP-WX8240 user manual Security Settings, Snmp

Page 32

3.Web Control

3.1Projector Web Control (continued)

3.1.9 Security Settings

Displays and configures passwords and other security settings.

Item

Description

User Account

Configures the user name and password.

 

User name

Configures the user name.

 

The length of the text can be up to 32 alphanumeric

 

 

characters.

 

Password

Configures the password.

 

The length of the text can be up to 255 alphanumeric

 

 

characters.

 

Re-enter Password

Reenter the above password for verification.

 

 

Configures the Authentication password for Network Control

Network Control

Port1 (Port: 23), Network Control Port2 (Port: 9715),

PJLink™ Port (Port: 4352), My Image Port (Port: 9716),

 

 

 

 

and Messenger Port (Port: 9719) (&22, 23).

 

Authentication

Configures the Authentication password.

 

The length of the text can be up to 32 alphanumeric

 

Password

 

characters.

 

 

 

Re-enter

 

 

Authentication

Reenter the above password for verification.

 

Password

 

SNMP

Configures the community name if SNMP is used.

 

Community name

Configures the community name. The length of the text can

 

be up to 64 alphanumeric characters.

 

 

Click the [Apply] button to save the settings.

NOTE • The new configuration settings are activated after restarting the network connection. When the configuration settings are changed, you must restart the network connection. You can restart the network connection from Network Restart on the main menu(&41).

• Only numbers ‘0-9’ and alphabet ‘a-z’, ‘A-Z’ can be used.

32

Image 32
Contents Trademark acknowledgment FeaturesThank you for purchasing this product Contents Manual network connection setting Wireless LANConnection to the network Network Presentation Web ControlNetwork Bridge Function Other FunctionsSecurity precautions when using wireless LAN Do not USE Near the FollowingConnection to the network System requirementsRequired equipment preparation Hardware and software requirement for computerQuick connection System requirementsManual network connection setting Wired LAN This section explains how to set it up manuallyNetwork settings Equipments connectionManual network connection setting Wired LAN About IP address Setting manually Setting automaticallyInternet Option setting Manual network connection setting Wireless LAN Preparation for wireless LAN connectionWireless Manual network connection setting Wireless LANWireless LAN connection set up About IP address Manual network connection setting Wireless LAN Network Presentation Web Control Logon User name Password Administrator BlankProjector Web Control Projector Web Control Network InformationLAN DhcpDisplays and configures network settings AMX D.DDhcp OFF Projector Web Control Network SettingsDhcp on Web Control Enables DhcpDisables Dhcp Port Settings Displays and configures communication port settingsProjector Web Control Port Settings Click the Apply button to save the settingsSend Test Mail Mail SettingsDisplays and configures e-mail addressing settings Alert Settings Displays and configures failure & alert settingsAlarm Time Only Lamp Time Alarm and Filter Time AlarmExcept Cold Start and Authentication Failure Snmp TrapSchedule Settings Displays and configures schedule settingsMessenger Description ScheduleDate Month/Day Projector Web Control Schedule Settings First, 2, 3, 4, Last Date/Time SettingsDisplays and configures the date and time settings Projector Web Control Date/Time Settings Time differenceSntp Sntp Server AddressSecurity Settings SnmpProjector Control Projector Web Control Projector Control Setup Auto Keystone Auto ECO ModeECO Mode InstallationAudio Volume SpeakerAudio Source Audio Source LANDirect Power on Auto Power OFFShade Timer Option Source SkipService Remote ReceivFront RearRemote Control Projector Web Control Remote Control Displays the settings and status of the projector Projector StatusNetwork Restart Restarts the projector’s network connectionWindow Crestron e-ControlClicking the corresponding tab at the top right Sources List Crestron e-ControlMain window Crestron e-Control- Main window Projector Tools windowCrestron Control Projector Configures the network settings of the projector User PasswordAdmin Password Crestron e-Control- Tools windowInfo window Projector InformationHelp Desk window Emergency Alert My Image Function OPTION menu in the Operating GuideMessenger Function Connecting devices Network Bridge FunctionOperating Guide Technical LAN port USB Type a port Control portCommunication setup Communication portControl port ConditionTransmission method HALF-DUPLEXTransmission method FULL-DUPLEXMail Alerts Mail Settings &24Other Functions Mail Alerts Projector Management using Snmp Snmp Settings &23Event Scheduling Schedule Settings &27 Event SchedulingDate/Time Settings &30 Communication Port Command Control via the NetworkFollowing two ports are assigned for the command control Command Control via the Network Command Format Reply Error codeHeader Data length RS-232Ccommand Check Sum Connection TCP #9715Reply Data format Authentication Automatic Connection BreakCrestron RoomView Troubleshooting Problem Likely Cause Things to CheckSpecifications Warranty and after-sales service