Dukane 8062, 8802 manual Operating the PC Screen, Available Functions Remote Control Operation

Page 25

OPERATING THE PC SCREEN

You can use the remote control as a simplified mouse or keyboard.

CAUTION Caution: Mistaken use of the mouse/keyboard control could damage your equipment.

Only connect to a PC.

Before connecting, read the manuals of the device you will connect.

Do not unplug the connector cables while the computer is operating.

 

 

 

STANDBY/ON

VIDEO

RGB

SEARCH

 

ASPECT

 

AUTO

BLANK

MAGNIFY

HOME

PAGE UP

VOLUME

ON

 

 

 

 

END

PAGE DOWN

MUTE

OFF

 

 

 

FREEZE

 

KEYSTONE

POSITION

 

 

MENU

 

ENTER

 

PS/2, ADB, Serial Mouse Control

1.Turn off the projector and PC power, and connect the projector’s CONTROL terminal to the computer via the mouse cable.

2.If a USB cable is connected, disconnect it. If a USB cable is connected, the USB control function is given priority, and mouse control from the CONTROL terminal will not function.

3.Turn on the projector power, then the computer.

The functions in the table below can be controlled. If you have difficulty with control, restart the computer (either from the software or by pressing the restart button).

Available Functions

Remote Control Operation

Move Pointer

Use

buttons

Left click with mouse

Press ENTER button

 

Right click with mouse

Press RESET button

 

ESC

RESET

USB Mouse/Keyboard Control

1.Connect the projector’s USB terminal to the computer using a USB cable. The functions in the table below can be controlled.

Available Functions

Remote Control Operation

 

 

 

Move Pointer

Use

buttons

 

 

 

Left click with mouse

Press ENTER button

 

 

 

 

Right click with mouse

Press RESET button

 

 

 

 

Press keyboard’s HOME key

Press HOME button

 

 

 

 

Press keyboard’s END key

Press END button

 

 

 

 

Press keyboard’s PAGE UP key

Press PAGE UP button

 

 

 

Press keyboard’s PAGE DOWN key

Press PAGE DOWN button

 

 

 

Press keyboard’s ESC key

Press ESC button

 

 

 

 

NOTES

It may not be possible to control notebook PCs, and other computers with built-in pointing devices (e.g. track balls), using this remote control. In this case, before connecting go into BIOS (system setup) and select external mouse, and disable the pointing devices. In addition, the mouse may not function if the computer does not have the needed utility program. See your computer’s hardware manual for details.

The USB control can be used with Windows 95 OSR 2.1 or higher. It may not be possible to use the remote control, depending on the computer’s configurations and mouse drivers.

The USB control can only be used for the functions listed above. You cannot do things like press two buttons at once (for instance, pressing two buttons at the same time to move the mouse pointer diagonally).

This function is not available while the lamp is warming up (the POWER indicator flashes green), while adjusting the volume and display, correcting for trapezoidal distortion, zooming in on the screen, using the BLANK function, or displaying the menu screen.

24

Image 25
Contents Models 8062/8802 Contents Power cord Projector FeaturesSoft carrying case Remote control US Type UK Type Europe Type Projector With Lens CapDevices you will be using to the projector Only use the power cord that came with the projectorPower cord Reference Part NamesFreeze button Keyboard buttons Auto button Blank button Volume button Mute buttonPosition button Cursor buttonsAdjusting the Projectors Elevator Feet Setting UP the ProjectorScreen Adjusting the Screen Size and Projection DistanceTop view Side view Connecting Your Devices Function Projector Port Connection Cables Ports and CablesConnecting to a Computer Connecting Your DevicesConnecting to a VCR Connecting to a DVD PlayerConnecting to a Display Monitor Putting batteries into the remote control unit Using the Remote ControlOperating the remote control Turning on the Power Selecting an Input Signal Turning OFF the Power Press the Volume button Adjusting the VolumePress Buttons to adjust Volume Temporarily Muting the SoundUse Buttons to adjust Position Adjusting the PositionPress the Position button Automatic Adjustment for RGB Input Using the Automatic Adjustment FeatureAutomatic Adjustment for Video Input Press the Auto buttonPress the Keystone button Correcting Keystone DistortionsAs illustrated on the right, a dialog will appear On the screen to aid you in correcting the distortionFreezing the Screen Using the Magnify FeatureSelecting the Aspect Ratio Signal SearchingTemporarily Blanking the Screen Select a menu using Buttons Then press Or Enter button Using the Menu FunctionsSelect an item using Buttons, then press Or Enter button Press Buttons to adjust the levelOperating the PC Screen Available Functions Remote Control OperationLamp High Voltage High Temperature High PressureDo not use the projector with the lamp cover removed Replacing the lamp Caring for the air filter AIR FilterReplacing the air filter Other Care Caring for the cabinet and remote control transmitterCaring for the inside of the projector Caring for the lensFor Technical see the end of this manual Main Menu Multifunctional SettingsMain Menu Picture 2 Menu Picture 1 MenuPICTURE1 Menu PICTURE2 MenuInput Menu Input MenuAuto VideoScreen Menu Screen MenuBlank Start UPOption Menu VolumeOption Menu Auto OFFRelated Messages Power Lamp Temp Regarding the Indicator LampsVol.2-2 Phenomena That May Easily Be Mistaken for Machine DefectsVol.2-3 Vol.2-6Dimension Diagram SpecificationsSpecification Unit mmWarranty and AFTER-SERVICE Signal Terminal Specification Signal Connector PIN AssignmentRGB in 1/2 Sub 15-pin ShrinkResolution FH kHz FV Hz Rating Signal mode Display mode Example of Computer SignalInitial SET Signals ADB Mouse Connection to the Mouse ControlSerial Mouse USB MouseConsist of header 7 bytes + command data 6 bytes Command dataRS-232C Communication ProtocolChanging the projector settings Set command Requesting projector status Get commandUsing the projector default settings Reset Command Increasing the projector setting value Increment command日本語 Command data chartBe EF BA D2 Be EF FD D3 Be EF Ntsc PAL Regulatory Notices Page Page Page Page Page Page Dukane Corporation Audio Visual Products 401-8062/8802

8062, 8802 specifications

The Dukane 8802 and 8062 ultrasonic welding systems represent a significant advancement in the field of ultrasonic technology, designed for precision joining of thermoplastics and metals. These systems combine innovative engineering with user-friendly features, making them an ideal choice for various industrial applications.

One of the defining features of the Dukane 8802 and 8062 is their robust ultrasonic generator that provides consistent power output. This ensures that every weld is reliable and repeatable, crucial for high-volume production environments. The systems utilize a patented Smart Generator technology, capable of automatically tuning to the optimal frequency, thus maximizing efficiency and enhancing acoustic performance.

Both models are equipped with a high-performance ultrasonic transducer, which converts electrical energy into mechanical energy. This transducer is designed for durability and long-term performance, ensuring minimal downtime and reduced maintenance needs. The systems also feature advanced piezoelectric materials that enhance energy conversion, leading to superior welding results.

User convenience is paramount, reflected in the digital touchscreen interface that allows operators to easily set parameters, monitor real-time performance, and adjust settings as necessary. Multiple welding modes are available, including time, energy, and distance control, allowing users to select the best approach according to their specific application needs.

The Dukane 8802 and 8062 also incorporate a lightweight and ergonomic design, facilitating easy integration into existing production lines. The adjustable horn and fixture options offer versatility in handling different component shapes and sizes, making these systems suitable for a wide range of industries including automotive, medical, and consumer goods.

Moreover, both systems emphasize safety and compliance, featuring built-in sensors that prevent overload conditions and ensure weld quality. This focus on safety enhances operator confidence and protects expensive tooling.

In conclusion, the Dukane 8802 and 8062 ultrasonic welding systems stand out due to their advanced technology, efficiency, and operator-friendly design. These characteristics not only improve manufacturing processes but also contribute to cost savings and higher quality standards across various applications.