Dukane 28A8910 user manual Be EF CB D0

Page 46

TECHNICAL (continued)

 

 

 

 

 

 

 

 

 

 

 

Command data chart

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Names

 

Operation type

 

Header

 

 

 

 

 

 

 

 

Command data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CRC

Action

Type

Setting code

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Set

 

off

BE EF

03

06

00

 

 

CB D0

01

00

08

30

01

00

Sync on G

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

on

BE EF

03

06

00

 

 

5B

D1

01

00

08

30

00

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Get

BE EF

03

06

00

 

 

68 D1

02

00

08

30

00

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Set

 

NORMAL

BE EF

03

06

00

 

 

3B 23

01

00

00

33

00

00

WHISPER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WHISPER

BE EF

03

06

00

 

 

AB 22

01

00

00

33

01

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Get

BE EF

03

06

00

 

08

23

02

00

00

33

00

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NORMAL

BE EF

03

06

00

 

 

C7 F0

01

00

A1 30

00

00

 

Set

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GAMMA

 

CINEMA

BE EF

03

06

00

 

57

F1

01

00

A1 30

01

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DYNAMIC

BE EF

03

06

00

 

 

A7

F1

01

00

A1 30

02

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Get

BE EF

03

06

00

 

 

F4

F0

02

00

A1 30

00

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Set

 

off

BE EF

03

06

00

 

 

FF 32

01

00

00

26

00

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IR Remote Front

 

on

BE EF

03

06

00

 

 

6F

33

01

00

00

26

01

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Get

BE EF

03

06

00

 

 

CC 32

02

00

00

26

00

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Set

 

off

BE EF

03

06

00

 

03

33

01

00

01

26

00

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IR Remote Rear

 

on

BE EF

03

06

00

 

93

32

01

00

01

26

01

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Get

BE EF

03

06

00

 

30

33

02

00

01

26

00

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Set

 

off

BE EF

03

06

00

 

47

33

01

00

02

26

00

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IR Remote Top

 

on

BE EF

03

06

00

 

 

D7 32

01

00

02

26

01

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Get

BE EF

03

06

00

 

74

33

02

00

02

26

00

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTEThe max. 2 IR remote out of 3 (front, rear and top) can be activated.

TECHNICAL - 12

Image 46
Contents 28A8910 Page Page Page Page Page Page Page Page Page Contents Contents of Package FeaturesBefore USE Part Names Transmitter Refer to P.9 OperationsLoading the Batteries Angle Adjustment InstallationInstallation of the Projector and Screen Installation ReferenceCabling CablingExample of system setup Power ConnectionPlug & Play Operations Power onPower OFF Equipment is used safelyAdjust Magnification Press the Magnify Image Position Adjustment PressSet Magnify Mode Press the Magnify Basic OperationNormal menu Setup Menu Setup MenuInput Menu Automatic Adjustment at RGB Input Select the Execute withAutomatic Adjustment at Video Input Select the Execute with Input MenuImage Menu Description Image MenuMyScreen Select Menu Background Color Select with Options MenuOptions Menu Select Menu Display Language Select withNo Signal Menu Description No Signal MenuReduce Increase Lamp MaintenanceLamp Lamp LifeResetting the Lamp Timer Replacing the LampOther Maintenance Air FilterOSD Message TroubleshootingMessage Contents OSD MessagesIndicators Message Indicators MessageIndicator Symptom SymptomSymptom Possible cause Remedy Specifications SpecificationsWarranty and AFTER-SERVICE Signal Connector Pin Assignment Dimension DiagramTechnical Example of computer signal TechnicalInitial set signals USB Mouse Connection to the Mouse ControlPS/2, ADB or Serial Mouse PS/2 MouseADB Mouse Serial MouseRS-232C communication Communications settingCommand data ProtocolUsing the projector default settings Reset Command Requesting projector status Get commandChanging the projector settings Set command Increasing the projector setting value Increment commandCRC Be EF BA D2 Be EF FD D3 Be EF Ntsc PAL Be EF CB D0 FCC Statement Warning Regulatory NoticesFor the Customers in Canada Pour les utilisateurs au Canada Page Legal Information Audio Visual Products