Dukane 28A8247 user manual Regarding the Indicator Lamps, Power Lamp Temp

Page 48

Regarding the Indicator Lamps

Lighting and flashing of the POWER indicator, the LAMP indicator, and the TEMP indicator have the meanings as described in the Table below. Please respond in accordance with the instructions within the Table.

POWER

LAMP

TEMP

Description

indicator

indicator

indicator

 

 

 

 

 

The orange

Turned OFF

Turned OFF

The STANDBY mode is set

lamp is lighted

(Not lighted)

(Not lighted)

 

 

 

 

 

Flashing of the green lamp

Turned OFF

Turned OFF

The unit is warming up. Please wait.

 

 

 

 

The green lamp is lighted

Turned OFF

Turned OFF

The unit is in an ON state. Ordinary operations may be performed.

 

 

 

 

Flashing of the orange lamp

Turned OFF

Turned OFF

The unit is cooling down. Please wait.

 

 

 

 

 

 

 

The unit is cooling down. Please wait.

Blinking of the

-

-

A certain error has been detected. Wait until the POWER indicator lamp has finished

red lamp

flashing, and then perform the proper response measure using the item descriptions

 

 

 

 

 

below as reference.

 

 

 

 

 

 

 

The lamp does not light.

The red lamp

The red lamp

Turned

There is a possibility that the interior portion has become heated. Turn the power OFF and wait

is lighted, or

approximately 20 minutes. After the main unit has cooled down, please confirm whether or not

is lighted

OFF

there is blockage of the air passage aperture, whether or not the filter is dirty, and/or whether or

blinks

 

 

not the peripheral temperature exceeds 35°C, etc. After performing any needed maintenance,

 

 

 

turn the power ON again; if the same display is displayed, then please change the lamp.

 

 

 

 

The red lamp

 

 

Either there is no lamp and/or lamp cover, or either of these has not been properly fixed

Blinking of the

Turned

(attached). Turn the power OFF and wait approximately 45 minutes. After the main unit has

is lighted, or

sufficiently cooled down, please make confirmation of the attachment state of the lamp and

red lamp

OFF

blinks

lamp cover. After performing any needed maintenance, turn the power ON again; if the same

 

 

 

 

 

display is displayed, then please contact a sales store or a service company.

 

 

 

 

The red lamp

Turned

Blinking of the

The cooling fan is not operating. Turn the power OFF and wait approximately 20 minutes. After the

is lighted, or

main unit has cooled down, please make confirmation that no foreign matter has become caught in

OFF

red lamp

the fan, etc. After performing any needed maintenance, turn the power ON again; if the same display

blinks

 

 

is displayed, then please contact a sales store or a service company.

 

 

 

 

 

 

 

There is a possibility that the interior portion has become heated. Turn the power OFF and wait

The red lamp is

Turned

The red lamp is

approximately 20 minutes. After the main unit has cooled down, please confirm whether or not

lighted, or

there is blockage of the air passage aperture, whether or not the filter is dirty, and/or whether or

OFF

lighted

not the peripheral temperature exceeds 35°C, etc. After performing any needed maintenance,

blinks

 

 

turn the power ON again; if the same display is displayed, then please contact a sales store or a

 

 

 

service company.

 

 

 

 

The green lamp

Alternative blinking

There is a possibility that the interior portion has become overcooled. Please use the unit within

the usage temperature parameters (0°C to 35°C). After performing any needed maintenance,

is lighted

with the red lamp

turn the power ON again; if the same display is displayed, then please contact a sales store or a

 

 

 

service company.

The green

Simultaneous blinking

This is a notification that it is time to clean the filter.

After cleaning the filter, operate the FILTER TIME portion of the OPTION Menu, and perform

lamp is lighted

with the red lamp

reset of the FILTER TIME.

 

 

 

 

 

 

 

NOTE

When the interior portion has become overheated, for safety purposes, the power source is automatically turned OFF, and the indicator lamps may also be turned OFF. Press the “” (power OFF) side of the main power switch, and wait for approximately 20 minutes. Please then use the unit only after having first confirmed that the unit has sufficiently cooled down.

9

Image 48
Contents Model 28A8247 Page Page Page Page Page Page Page Contents Projector Features RGB cable Video/Audio cable Vol.1/Vol.2 Safety InstructionsSoft carrying case Remote control US Type UK Type Europe Type Projector With Lens CapOnly use the power cord that came with the projector Devices you will be using to the projectorPart Names ProjectorRemote Control Setting UP the Projector Adjusting the Projectors Elevator FeetPress and hold in the elevator Buttons Turn the elevator screw to fine tuneAdjusting the Screen Size and Projection Distance ScreenTop view Side view Connecting Your Devices Ports and Cables Function Projector Port Connection CablesConnecting Your Devices Connecting to a ComputerBNC Input DVI Input A a aConnecting to a DVD Player Connecting to a VCRConnecting to a Display Monitor Using the Remote Control Putting batteries into the remote control unitRemove the battery cover Close the battery coverUsing the Remote Control Operating the remote controlRemote control in an area free from obstacles Meters with a 40-degree rangeTurning on the Power Turning on the Power Selecting an Input SignalTurning OFF the Power Adjusting the Volume Press the Volume buttonUse the lever switch / to adjust the volume Temporarily Muting the SoundAdjusting the Position Use the , , , buttons to adjust the positionPress the Position button Using the Automatic Adjustment Feature Automatic Adjustment for RGB InputAutomatic Adjustment for Video Input Press the Auto buttonCorrecting Keystone Distortions Press the Keystone buttonAs illustrated on the right, a dialog will appear On the screen to aid you in correcting the distortionUsing the Magnify Feature Freezing the ScreenAdjusting Screen with ONE-TOUCH Was begun When BNC RGB is selectedPress the ONE Touch button You can activate the following functions just bySelecting the Aspect Ratio Temporarily Blanking the ScreenPress the Aspect button Press the Blank buttonUsing the Menu Functions Use the lever switch To adjust the levelPress the Menu button Available Functions Remote Control Operation Operating the PC ScreenHigh Voltage High Temperature High Pressure LampDo not use the projector with the lamp cover removed Lamp Replacing the lampAIR Filter Caring for the air filterAIR Filter Replacing the air filterCaring for the cabinet and remote control transmitter Other CareCaring for the inside of the projector Caring for the lensFor Technical see the end of this manual Multifunctional Settings Main MenuMain Menu Item selectionPICTURE-1 Menu PICTURE-2 MenuPICTURE-1 Menu PICTURE-2 MenuMultifunctional Settings Input MenuInput Menu Auto Menu Auto Menu Screen Menu Screen Menu Blank Start UPWireless Menu Option MenuOption Menu IR RemoteRelated Messages No Input is DetectedSync is OUT of Range Check the AIR FlowRegarding the Indicator Lamps Power Lamp TempPhenomena That May Easily Be Mistaken for Machine Defects Vol.2-2Vol.2-3 PhenomenonSpecifications Dimension DiagramSpecification Unit mmSignal Connector PIN Assignment Signal Terminal SpecificationSub 15-pin Shrink Example of Computer Signal Resolution FH kHz FV Hz Rating Signal mode DisplayInitial SET Signals Connection to the Mouse Control ADB MouseUSB Mouse PS/2 MouseCommand data Consist of header 7 bytes + command data 6 bytesRS-232C Communication ProtocolRS-232C Communication Command data chart 日本語Be EF BA D2 Be EF AD D0 Be EF CB D0 Legal Information Audio Visual Products