CH Tech i4000 user manual Vmebus Interface, Address Interface

Page 15

i4000 - Quad M-module carrier for VMEbus

 

User Manual

Version: 1.2

4.VMEBUS INTERFACE

4.1.ADDRESS INTERFACE

The i4000 can be selected to accept either short addressing, using 16-bit addresses (A16) or standard addressing, using 24-bit addresses (A24).

When using short addressing up to 32 i4000 boards can be put in a single VMEbus system since the lower 11 address lines (A0-A10) are used internally on the i4000. If standard addressing is used, a larger address space is available to select the board.

The memory space occupied by the i4000 is 0x800 bytes long. This memory space is equally spread across the four modules. So each module occupies 0x200 bytes. From these 0x200 bytes address space half is used by the interrupt controller. The address space for each module is therefore 0x100 bytes long (8 bit addressing).

The address space of the i4000 is selectable using dip switches (SW1 and SW2) which are accessible even when the four module slots are occupied. When a switch is “on” the corresponding address line is a logical “zero” and when a switch is “off” the corresponding address line is “one”.

Address modifier AM4 can be used to select either standard or short memory addressing. If AM4 is “one” (the switch is in the off position) standard addressing is selected. If AM4 is “zero” (switch on) short addressing is selected. When using short addressing the address lines A16-A23 are don’t cares.

E X A M P L E :

O f f

O n

1

2

3

4

5

6

7

8

1

2

3

4

6

7

O f f

A 2 3

O n

A 2 2

O n

A 2 1

O f f

A 2 0

O n

A 1 9

O n

A 1 8

O n

A 1 7

O n

A 1 6

O n

A 1 5

O n

A 1 4

O n

A 1 3

O n

A 1 2

O f f

A 1 1

O f f

A M 4

Base Adress

SW2

0x900800

SW3

( s t a n d a r d a d d r e s s s p a c e )

Figure 4 Address Selection

AcQuisition Technology bv

 

P.O. Box 627, 5340 AP

 

Oss, The Netherlands

Page 15 of 25

Image 15
Contents I4000 Page Contents Page Introduction Page Product Overview IntroductionTechnical Overview Page Unpacking the Hardware Installation and SetupModule component side Connectors Mounting AN M-MODULE2. P2 Connector Assignments I4000/P2 only Page Module component side Module Interface ConnectorPage Address Interface Vmebus InterfaceInterrupter SW1Dipswitch Locations BG0OUT Vmebus P1 Connector AssignmentsReset BG0INRegister Description Block DiagramExample Address MappingReserved Interrupt Controller ResetControl Register RES IRE IracPage Annex Component ImageBibliography Document History Technical Data