Specifications and Characteristics
AC Line Input Specifications
236 Operating Manual for XDC Series Power Supply
AC Line Input Specifications

The input to the power supply requires the following specifications.

AC Line Input

Voltage

Operating

Ranges Table E.9 AC Line Input Specifications
Operating Range
nominal 208Vrms (Standard)
nominal 400Vrms (with HV-Input option)
190 to 242 Vac 3 φ (3 wire + safety
ground)
342 to 500 Vac 3 φ (3 wire + safety
ground)
Frequency Range 47 to 63 Hz
Maximum Peak In-rush Current at turn on 35 Arms (6000 Watt)
70 Arms (12000 Watt)
Minimum Power Factor1
nominal 208Vrms (Standard)
nominal 400Vrms (with HV-Input option)
0.95
0.9
Operating Current
nominal 208Vrms (Standard)
Maximum2
Typical3
24 A (6000 Watt)
48 A (12000 Watt)
20 A (6000 Watt)
40 A (12000 Watt)
Operating Current
nominal 400Vrms (with HV-Input option)
Maximum4
Typical5
13 A (6000 Watt)
26 A (12000 Watt)
11A (6000 Watt)
22 A (12000 Watt)
1. At nominal input voltage and maximum power
2. At 190Vac input voltage, 55°C ambient temperature and maximum power
3. At 208Vac input voltage, 25°C ambient temperature and maximum power
4. At 342Vac input voltage, 50°C ambient temperature and maximum power
5. At 400Vac input voltage, 25°C ambient temperature and maximum power