Remote Operation

SCPI Commands for Digital Interfaces

TEMPerature Sub-Register

This shows whether the temperature of critical components is near or over the maximum operating temperature.

Table 4.19 TEMPerature Sub-Register

Bit

Bit Weight

Bit Name

Description

0

1

Over TEMperature

Set if the power supply temperature

 

 

 

exceeds the maximum operating

 

 

 

temperature.

1

2

High TEMperature

Set if the power supply temperature

 

 

 

exceeds 90% of the maximum

 

 

 

operating temperature.

Standard Event Status Register

The standard event status register sets bits for specific events during power supply operation. All bits in the standard event status registers are set through the error event queue. The register is defined by 488.2 and is controlled using 488.2 common commands, *ESE, *ESE?, and *ESR?.

Figure 4.6 summarizes the standard Event Status Register

Operation Complete

0

 

 

 

 

Not Used

1

 

 

 

 

Query Error

2

 

Not Used

0

Device Dependent Error

3

 

 

Not Used

1

 

Execution Error

4

 

 

 

Not Used

2

 

Command Error

5

 

 

 

Summary of QUESTionable Status

3

 

User Request

6

 

 

 

MAV

4

 

Power On

7

+

 

 

5

 

Reserved

8

RQS/MSS

 

 

6

 

Reserved

9

 

 

 

Summary of OPERation Status

7

 

Reserved

10

 

 

 

 

 

 

Reserved

11

 

Status Byte

 

 

Reserved

12

 

 

 

 

 

 

 

Reserved

13

 

 

 

 

Reserved

14

 

 

 

 

Reserved

15

 

 

 

 

Standard Event Status Register

 

 

Standard Event Status Register

 

 

 

Figure 4.6

IEEE 488.2 Status Register and Status Byte

 

Release 3.0

153

Page 155
Image 155
Xantrex Technology XDC manual TEMPerature Sub-Register, Standard Event Status Register