Specifications and Characteristics
Output Performance Specifications
240 Operating Manual for XDC Series Power Supply
User Line Interface
Includes auxiliary status lines, interlock, and external trigger lines.
Switching Frequency
Typical 31kHz; 62 kHz output ripple
Rise Time
5 to 95% step in output voltage.
Fall Time
For a programmed 95% to 5% step in output voltage.
Time Delay From Power On Until Output Stable
5 s maximum
(Within regulation envelope)
Time Delay From Output Enable Until Output Stable
2 s maximum
(Within regulation envelope)
Output Hold-Up Time – Power Off
Minimum 4 ms (at full load)
Maximum Current Sink
Capability, Each Output 10 mA
Maximum Supply Voltage 15 Vdc
Minimum Supply Voltage 4 Vdc
Isolation 300 Vdc with respect to chassis
potential or negative output
Load Condition Time (Max)
No Load 100 ms
Full Load 100ms
Load Condition Time (Max)
No Load 1
1. Fall time is 4s for 300V and 600 V units.
3s
Full Load 50 ms