Specifications and Characteristics

Output Performance Specifications

User Line Interface

Includes auxiliary status lines, interlock, and external trigger lines.

Maximum Current Sink

 

Capability, Each Output

10 mA

Maximum Supply Voltage

15 Vdc

Minimum Supply Voltage

4 Vdc

Isolation

300 Vdc with respect to chassis

 

potential or negative output

Switching Frequency

Typical 31 kHz; 62 kHz output ripple

Rise Time

5 to 95% step in output voltage.

Load Condition

Time (Max)

No Load

100 ms

 

 

Full Load

100 ms

 

 

Fall Time

For a programmed 95% to 5% step in output voltage.

Load Condition

Time (Max)

No Load 1

3 s

Full Load

50 ms

1. Fall time is 4s for 300 V and 600 V units.

Time Delay From Power On Until Output Stable

5 s maximum

(Within regulation envelope)

Time Delay From Output Enable Until Output Stable

2 s maximum

(Within regulation envelope)

Output Hold-Up Time – Power Off

Minimum 4 ms (at full load)

240

Operating Manual for XDC Series Power Supply

Page 242
Image 242
Xantrex Technology XDC manual Typical 31 kHz 62 kHz output ripple, To 95% step in output voltage, Minimum 4 ms at full load