About The XDC Power Supply
Front Panel
Release 3.0 25
8. PROTECTION SET key: View and set protection setpoints.
ALARM response: Read and clear alarm messages. ALARM annunciator
indicates if there are any alarm messages.
9. RECALL settings key: Apply stored power supply settings.
10. EXIT key: Cancel operation, exit menu or get out of Calibration mode or Auto
Sequence mode. Automatic timeout will also cancel operation except calibration
and auto sequence operation.
11. Numeric keypad: Numbers 0 to 9, used for data entry.
12. Decimal key: Enter a decimal. Used for data entry.
13. CE key: Clear the entire data field. Used for data entry. In Store User Setting
mode, used to delete selected setting or program.
14. Up arrow key: Scroll through menus and lists, or, in data entry mode, increase
the displayed value. In default operating mode, use this key to view the output
power. In Auto Sequence Operating mode, use this key to view present sequence
number, step numbers, and sequence loop count.
15. Down arrow key: Scroll through menus and lists, or, in data entry mode,
decrease the displayed value.
16. ENTER key: Select a menu item or accept data.
17. MENU key: Access all menu functions.