Remote Operation

SCPI Commands for Digital Interfaces

VOLTage Sub-Register

This shows whether the present voltage level is over or under the specified trip limit.

Table 4.16 VOLTage Sub-Register

Bit

Bit Weight

Bit Name

Description

0

1

Over VOLtage

Set if the supply’s output voltage

 

 

 

exceeds the over-voltage trip level,

 

 

 

either user-specified variable trip limit,

 

 

 

or the fixed trip limit.

1

2

Under VOLtage

Set if the supply’s output voltage is less

 

 

 

than the user-specified under-voltage

trip level (variable trip limit) and the supply is in Operation state.

CURRent Sub-Register

This shows whether the present current level is over or under the specified trip limit.

Table 4.17 CURRent Sub-Register

Bit

Bit Weight

Bit Name

Description

0

1

Over CURrent

Set if the supply’s output current is

 

 

 

greater than the user-specified

 

 

 

over-current trip level (variable trip limit)

 

 

 

and the supply is in Operation state.

1

2

Under CURrent

Set if the supply’s output current is less

 

 

 

than the user-specified under current

 

 

 

trip level (variable trip limit) and the

 

 

 

supply is in Operation state.

 

 

 

 

POWer Sub-Register

This shows whether the present power level is over or under the specified trip limit.

Table 4.18 POWer Sub-Register

Bit

Bit Weight

Bit Name

Description

0

1

Over POWer

Set if the supply’s output power is

 

 

 

greater than the user-specified

 

 

 

over-power trip level (variable trip limit),

 

 

 

and the supply is in Operation state.

1

2

Under POWer

Set if the supply’s output power is less

 

 

 

than the user-specified under-power trip

 

 

 

level (variable trip limit), and the supply

 

 

 

is in Operation state.