Remote Operation

Multichannel Operation (6000 Watt only)

Multichannel Add a suffix of "0" to simultaneously broadcast the "command" to the master and all Broadcast other units on the CANbus. Only commands are allowed, queries are not allowed.

Commands Note that there will be a lag in execution time between the local unit and all other units of up to a maximum of 20 ms. For example:

SOURCE0:VOLT 10.0

will set all units in a multichannel string to 10.0 V

Specifications

Max connected units

50

Max cable length

40 m

 

 

Bus speed

700 kbits/sec

 

 

Termination

120 ohm 1/4 W

 

 

Connections

parallel male DB9 to female DB9 cable

 

 

Addresses

1 to 50

 

 

Release 3.0

117

Page 119
Image 119