Remote Operation
SCPI Commands for Digital Interfaces
Release 3.0 151
Table 4.15QUEStionable Status Register
Bit Bit Weight Bit Name Description
0 1 VOLTage Summary Reflects a summary of the
VOLTage Sub-Register.
1 2 CURRent Summary Reflects a summary of the
CURRent Sub-Register.
2 4 TIME Not implemented
3 8 POWer Summary Reflects a summary of the POWer
Sub-Register.
4 16 TEMPerature Summary Reflects a summary of the
TEMPerature Sub-Register.
5 32 FREQuency Summary Not implemented
6 64 PHASe Summary Not implemented
7 128 MODulation Summary Not implemented
8 256 CALibration Indicates an error in the unit
calibration.
9 512 Not Used Not implemented
10 1024 Not Used Not implemented
11 2048 AC Off Indicates an AC Supply failure.
12 4096 UNRegulated Indicates that the output is not
regulated in either Constant
Voltage mode, Constant Current
mode or Constant Power mode.
Reflects the inverse of the
Operation Regulation Summary bit.
13 8192 INSTrument Summary Not implemented
14 16384 Command Warning Not implemented
15 32768 Not Used Always zero